BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

First published online April 26, 2006
British Journal of Radiology (2006) 79, 636-643
© 2006 British Institute of Radiology
doi: 10.1259/bjr/57301879

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hamer, O W
Right arrow Articles by Zorger, N
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hamer, O W
Right arrow Articles by Zorger, N

Full paper

In vitro evaluation of stent patency and in-stent stenoses in 10 metallic stents using MR angiography

O W Hamer, MD I Borisch, MD C Paetzel, MD W R Nitz, PhD J Seitz, MD S Feuerbach, MD and N Zorger, MD

Department of Radiology, University Hospital of Regensburg, Franz-Josef-Strauss-Allee 11, 93042 Regensburg, Germany

In vitro study to investigate the suitability of contrast enhanced magnetic resonance angiography (CEMRA) for determination of stent patency and grading of in-stent stenoses in 10 metallic stents. The Acculink carotid, DynaLink, Easy Wallstent, JostentSelfX XF, Luminexx, Omnilink, sinus-SuperFlex, SMART, Symphony and ZA stent were separately placed in a vascular phantom. Dedicated stenoses inside the stents generated a concentric lumen narrowing of 50%. CEMRA was performed for each stent. Signal loss inside the stents and artificial lumen narrowing were assessed objectively using the evaluation software of the MR imager. Moreover, three blinded observers determined visibility of stent patency and in-stent stenoses subjectively on a 3-point scale and graded in-stent stenoses. Loss of signal intensity within the stent lumen ranged between 90% (Wallstent) and 5% (ZA), artificial lumen narrowing between 56% (Symphony) and 22% (ZA). For the Symphony and Wallstent, visibility of patency and in-stent stenoses was impaired and the observers' grading exaggerated the degree of stenoses (by 23% and 33%, respectively). For the remainder of stents, patency and stenoses were visible and stenoses were graded accurately (less than 10% discrepancy from reference standard). In this in vitro study, eight of 10 stents presented with MRI characteristics which enabled determination of stent patency and accurate grading of clinically relevant in-stent stenoses.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2006 by the British Institute of Radiology.