BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2003) 76, 648-652
© 2003 British Institute of Radiology
doi: 10.1259/bjr/25693100

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jervis, S E
Right arrow Articles by Brettle, D S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jervis, S E
Right arrow Articles by Brettle, D S

Short communication

A practical approach to soft-copy display consistency for PC-based review workstations

S E Jervis, MSc and D S Brettle, MSc

Department of Medical Physics & Engineering, Leeds Teaching Hospitals NHS Trust, St James's University Hospital, Leeds LS9 7TF, UK

The use of non-permanent, digital image display, i.e. soft-copy display, is increasing within hospitals due to the growth in the use of digital modalities and picture archiving and communication systems (PACS). Non-dedicated image review using standard PCs is being employed as a cost-effective method of image access. These workstations do not have specialized display systems and are likely to suffer from inconsistent image presentation. The Digital Imaging and Communications in Medicine (DICOM) Working Group 11 has developed a display function standard (part 14) to standardize the display of grey scale images. Although this standard is starting to be adopted by manufacturers of proprietary reporting systems it is not easily applied to the existing number of non-dedicated, PC-based review systems. The aim of this work was to investigate whether display consistency could be achieved simply and reproducibly on these systems, outside of the DICOM standard: part 14, by adjusting monitor brightness and contrast settings and using the Society of Motion Picture and Television Engineers (SMPTE) digital test pattern. The study showed that by adjusting the brightness and contrast settings alone it was possible to approximate the display characteristic curves to the grey scale standard display function (GSDF) defined in the DICOM standard: part 14, but only at unacceptably low luminances. Intradisplay and interdisplay consistency could be achieved using a simple monitor set-up procedure and the SMPTE test pattern.




This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
D S Brettle
Display considerations for hospital-wide viewing of soft copy images
Br. J. Radiol., July 1, 2007; 80(955): 503 - 507.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. J. Robson and C. J. Kotre
Pilot study into optimisation of viewing conditions for electronically displayed images
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 298 - 303.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
D S Brettle and S E Bacon
A method for verified access when using soft copy display
Br. J. Radiol., August 1, 2005; 78(932): 749 - 751.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
W. Berkhout, D. Beuger, G. Sanderink, and P. van der Stelt
The dynamic range of digital radiographic systems: dose reduction or risk of overexposure?
Dentomaxillofac. Radiol., January 1, 2004; 33(1): 1 - 5.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2003 by the British Institute of Radiology.