BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2003) 76, 104-108
© 2003 British Institute of Radiology
doi: 10.1259/bjr/75640835

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dale, E
Right arrow Articles by Olsen, D R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dale, E
Right arrow Articles by Olsen, D R

Full Paper

Comparative analyses of the dynamic properties of the rectum studied by cryo-sections of human cadavers and pelvic CT scans of patients

E Dale, PhD1,2, T P Hellebust, MSc1, Ø S Bruland, MD, PhD3 and D R Olsen, PhD1,2

1 Centre for Training and Research in Radiotherapy, Departments of 2 Medical Physics and 3 Radiotherapy, The Norwegian Radium Hospital, University of Oslo, Oslo, Norway

Correspondence: E Dale, Department of Medical Physics, The Norwegian Radium Hospital, N-0310 Oslo, Norway

Optimization of radiotherapy treatment plans based on dose–volume histograms relies on accurate organ delineation. Hollow organs, such as the rectum, are difficult and time-consuming to delineate owing to unclear visualization of the border between wall tissue and filling. Automated hollow organ delineation would be a valuable tool, but its development depends upon improved understanding of the dynamics of the rectum in response to filling. Two reasonable assumptions proposed in the literature are that (1) the rectal wall tissue along a constant length of the rectal cylinder is preserved over time and (2) the rectal wall tissue is distributed homogeneously along the cylinder. Therefore, variations in wall thickness can be explained by variable rectal filling. To investigate these assumptions, transversal cross-sectional areas enclosed by the outer contour (Aout) and inner contour (Ain) of the rectum were recorded from digital photographs of cadaver cryo-sections from the U.S. National Library of Medicine's Visible Human Project. In addition, Aout and Ain were recorded from 19 CT scans of 5 of our own patients. The transversal cross-sectional area of the wall of the rectum, Awall=Aout-Ain, was calculated. The data derived both from cryo-sections and repetitive CT scans of patients, revealed that there was a significant correlation between Awall and Aout, in contradiction to assumption (1) stated above (male cryo-sections: p<0.001, female cryo-sections: p=0.03, repetitive CT scans p<0.001). Moreover, the mean Awall calculated from one CT scan differed significantly from the mean Awall from other CT scans and was correlated with the mean Aout, i.e. rectal filling (p<0.001). This finding was confirmed by careful analysis of another study (p=0.001) and opposes assumption (2). Hence, the amount of wall tissue within a constant length of rectum is not preserved over time, but increases with increased filling. This implies that the longitudinal length of the rectum decreases in response to distension of the organ.




This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
E Dale, T P Hellebust, O S Bruland, and D R Olsen
Comparative analyses of the dynamic properties of the bladder wall studied by repetitive pelvic CT scans of patients and cryo-sections of cadavers
Br. J. Radiol., June 1, 2005; 78(930): 528 - 532.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2003 by the British Institute of Radiology.