BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McRobbie, D W
Right arrow Articles by Quest, R A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McRobbie, D W
Right arrow Articles by Quest, R A
British Journal of Radiology 75 (2002),523-531 © 2002 The British Institute of Radiology

Full Paper

Effectiveness and relevance of MR acceptance testing: results of an 8 year audit

D W McRobbie, PhD and R A Quest, MSc

Radiological Sciences Unit, The Hammersmith Hospitals NHS Trust & Imperial College, Charing Cross Hospital, Fulham Palace Road, London W6 8RF, UK

The effectiveness and relevance of independent acceptance testing was assessed by means of an audit of acceptance procedures for 17 MRI systems, with field strengths in the range 0.5–1.5 T, acquired over 8 years. Signal-to-noise ratio and geometric linearity were found to be the image quality parameters most likely to fall below acceptable or expected standards. These received confirmed successful corrective action in 69% of instances. Non-uniformity, ghosting and poor fat suppression were the next most common non-compliant parameters, but yielded less satisfactory outcomes. Spatial resolution was not found to be a sensitive parameter in determining acceptability. 49% of all non-compliant parameters received verifiable corrective attention. A schedule of actual acceptance criteria is presented and shown to be reasonable. Parameter failure rates were shown not to have improved with time. A safety audit of 11 of the installations revealed the most common failings to be inadequate suite layout and poor use of signs. The mean number of safety issues per installation identified as requiring attention was 5, from a questionnaire of 100 points. A number of anecdotal errors and omissions are reported. The data support the importance of an appropriate acceptance procedure for new clinical MRI equipment and for the involvement of a suitably qualified safety adviser on the project team from the outset.




This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
C J Koller, J P Eatough, P J Mountford, and G Frain
A survey of MRI quality assurance programmes.
Br. J. Radiol., July 1, 2006; 79(943): 592 - 596.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. Zhuo and R. P. Gullapalli
AAPM/RSNA Physics Tutorial for Residents: MR Artifacts, Safety, and Quality Control
RadioGraphics, January 1, 2006; 26(1): 275 - 297.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2002 by the British Institute of Radiology.