British Journal of Radiology 74 (2001),675-676 © 2001 The British Institute of Radiology

Commentary

In the eyes of the beholder: what we see is not what we get

B J J Abdullah, FRCR and K-H Ng, PhD, MIPEM

Department of Radiology, University of Malaya Medical Centre, 59100 Kuala Lumpur, Malaysia


    Introduction
 Top
 Introduction
 References
 
"He saw; but blasted with excess light, Closed his eyes in endless night"
The Progress of Poesy, Thomas Gray

Today, imaging is at the heart of the health care system. Accuracy of diagnosis and ultimately the efficacy of radiological diagnosis greatly depend on the conditions under which radiographs and images are viewed. These conditions include the luminance of the display devices (view boxes and display monitors) as well as the ambient room illumination or the amount of light falling on the viewing surface. Extensive psychophysical and clinical research has established the fact that lesion detectability declines when viewing conditions are not optimized. Sad to say, although viewing of radiographic images is a vital link in the imaging chain, it is not accorded much importance and the radiology community has given it scant attention.

The fact that there is no one apparent internationally agreed standard for clinical practice underscores the lack of focus on this issue, although attempts have been made to establish standards and guidelines. Quality control of view boxes has been recommended in the UK, and a luminance uniformity standard is given in "Practical guide to quality assurance in medical imaging" [1]. This standard stipulates that the brightness levels of the centre and in each quadrant of the view box should be within 10% of the mean value. It is also recommended that the level of illumination in the room under normal clinical film viewing conditions should not exceed 100 lux. One of the viewing conditions stated by the European guidelines [2] is that "The light intensity incident on the viewer's eye should be about 100 cdm-2. To achieve this, the brightness of the film illuminator should be between 2000 and 4000 cdm-2 for films in the density range 0.5 to 2.2." However, these recommendations have not been generally adopted as part of the routine quality assurance programme of radiology departments.

Both the Royal College of Radiologists [3] and the American College of Radiology (ACR) [4] guidelines and standard for teleradiology recommend monitor luminance of at least 50 ft-L (171.3 cdm-2). However, the ACR merely suggest that "Care should be taken to control lighting in the reading room to eliminate reflections in the monitor and to lower the ambient light as much as is feasible."

The most comprehensive guidelines on view box and viewing conditions is the mammography quality control established by the ACR and the American Cancer Society [5]. They recommend that "The luminance of a mammographic viewbox should be at least 3,000 to 3,500 nit (cdm-2). The room ambient illumination level should be 50 lux or less."

A summary of all international regulations and guidelines has been compiled by Smartlight Inc. [6]. Perhaps it is pertinent to mention a new generation of digital view boxes that meet these requirements and promise to improve diagnostic efficacy [6].

Even though there is a trend towards increased utilization of soft copy viewing, the vast majority of facilities worldwide, especially those in less developed countries, still rely on view boxes to display and read films. As computed radiography, picture archiving and communication systems (PACS) and teleradiology gain popularity, the luminance of display monitors and the quality of soft copy reporting become important quality issues.

In the past, the number, location and size of rooms were important considerations. Today, soft copy requires additional considerations, for example lighting and ergonomics. These considerations have an impact on the radiologist's comfort, accuracy and speed in soft copy interpretation [7]. As ambient room illuminance levels increase, diagnostic accuracy declines and the degree of fatigue also increases. The greatest problem in any reading area is that of lighting: glare, reflection, scatter and inability to control lighting levels. There appears to be unanimous agreement in support of the view that low levels of room illuminance are necessary for optimal viewing conditions. A few studies have demonstrated that luminance does not have much influence on detection and subsequent diagnosis [8–10]. More research is needed to confirm this finding.

With the above scenario in mind, we recommend the following:

  1. Establish international standards and guidelines for display device luminance and ambient illuminance.
  2. Standardize measurement units for luminance (many units are currently used, such as cdm-2, nit, ft-L) and establish calibration facilities for luminance meters.
  3. Establish a protocol for performance evaluation and routine quality control of display devices.
  4. Encourage and fund basic and applied psychophysical research on radiology viewing (soft copy reporting).
  5. Introduce the basics of radiology viewing in the education and training programmes of radiologists, radiographers and medical physicists.
  6. Provide guidelines on the design of reporting rooms using view boxes, display monitors, or a hybrid. Ergonomic requirements should play an important part in the design.

It would be appropriate for the British Institute of Radiology and the Institute of Physics and Engineering in Medicine to take the lead and set up a joint working party to address this crucial issue that has a significant impact on radiological diagnosis.

Received for publication October 20, 2000. Revision received January 24, 2001. Accepted for publication March 7, 2001.


    References
 Top
 Introduction
 References
 

  1. Moores BM, Watkinson SA, Henshaw ET, Pearcy BJ. Practical guide to quality assurance in medical imaging. Chichester, UK: John Wiley & Sons, 1991.
  2. The European Commission. European guidelines on quality criteria for diagnostic radiographic images, EUR16260 EN. Luxembourg: CEC, 1996.
  3. Board of the Faculty of Clinical Radiology, The Royal College of Radiologists. Guide to information technology in radiology: teleradiology and PACS. London: RCR, 1999.
  4. American College of Radiology. ACR standard for teleradiology. Reston, VA: ACR, 1998. [http://www.acr.org/cgi-bin/fr?tmpl:standards00,pdf:pdf/teleradiology.pdf]
  5. American College of Radiology. ACR mammography quality control. Reston, VA: ACR, 1999.
  6. International quality regulations radiographic film reading. New Jersey: Smartlight Inc, 1997. [http://www.smartlight.com]
  7. Siegel E, Reiner B, Abiri M, Chacko A, Morin R, Ro DW, et al. The filmless radiology reading room: a survey of established picture archiving and communication system sites. J Digit Imaging 2000;13(2 Suppl. 1):22–3.[Medline]
  8. Hill SJ, Faulkner K, Law J, Starritt HC. Film viewing conditions in mammography. Br J Radiol 1997;70:409–11.[Abstract]
  9. Rill LN, Huda W, Gkanatsios NA. View box luminance measurements and their effect on reader performance. Acad Radiol 1999;6:521–9.[Medline]
  10. Wang J, Anderson J, Lane T, Stetson C, Moore J. Contrast-detail characteristic evaluations of several display devices. J Digit Imaging 2000;13(2 Suppl. 1):162–7.[Medline]



This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
C. T. Lau and W. B. Gefter
The Electronic Viewbox
Am. J. Roentgenol., March 1, 2005; 184(3): 1021 - 1023.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E McCarthy and P C Brennan
Viewing conditions for diagnostic images in three major Dublin hospitals: a comparison with WHO and CEC recommendations
Br. J. Radiol., February 1, 2003; 76(902): 94 - 97.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Abdullah, B J J
Right arrow Articles by Ng, K-H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Abdullah, B J J
Right arrow Articles by Ng, K-H


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS