BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2005) 78, 733-736
© 2005 British Institute of Radiology
doi: 10.1259/bjr/25662922

This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vakhtangandze, T
Right arrow Articles by Rees, M R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vakhtangandze, T
Right arrow Articles by Rees, M R

The effect of Butterworth and Metz reconstruction filters on volume and ejection fraction calculations with 99Tcm gated myocardial SPECT

T Vakhtangandze, MD, PhD 1,2 D O Hall, PhD 3 F V Zananiri, PhD 3 and M R Rees, FRCP, FRCR 2

1 Department of Nuclear Medicine, Institute of Radiology and Interventional Diagnostics, Tbilisi, Georgia, 2 Department of Radiology, Bristol University, Bristol and 3 Department of Medical Physics and Bioengineering, United Bristol Healthcare Trust, Bristol, UK



View larger version (16K):

[in a new window]
 
Figure 1. (A) Calculated left-ventricular volumes; (B) Left-ventricular ejection fractions (LVEF). Metz filter {graysqu} Butterworth filter {blacksquare}. ESV, end systolic volume; EDV, end diastolic volume; SV, stroke volume.

 


View larger version (13K):

[in a new window]
 
Figure 2. End-diastolic volume ({blacklozenge}) and end-systolic volume ({blacksquare}) calculated with Metz and Butterworth Filters.

 


View larger version (12K):

[in a new window]
 
Figure 3. Comparison of left-ventricular ejection-fraction (LVEF) calculated with Metz and Butterworth filters.

 


View larger version (13K):

[in a new window]
 
Figure 4. Left-ventricular ejection-fraction (LVEF) calculated with Butterworth ({blacklozenge}) and Metz ({blacksquare}) filters, and difference between LVEF calculations ({blacktriangleup}), compared with defect size measured by Myoquant Index.

 


View larger version (13K):

[in a new window]
 
Figure 5. End-systolic volumes calculated with Butterworth ({blacklozenge}) and Metz ({blacksquare}) filters, and the difference between these ({blacktriangleup}), compared with the Myoquant Index.

 





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2005 by the British Institute of Radiology.