BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2004) 77, 666-671
© 2004 British Institute of Radiology
doi: 10.1259/bjr/13566913

This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsalafoutas, I A
Right arrow Articles by Yakoumakis, E N
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsalafoutas, I A
Right arrow Articles by Yakoumakis, E N

Variation of the sensitometric characteristics of seven mammographic films with processing conditions

I A Tsalafoutas, PhD1, A D Dimakopoulou, MSc2, E D Koulentianos, MD, PhD3, A N Serefoglou, MD, PhD2 and E N Yakoumakis, PhD2

1 Medical Physics Unit and 3 Radiology Department "Konstantopoulio - Agia Olga" Hospital, 3–5 Agias Olgas, Nea Ionia, 142 33, Athens and 2 Medical Physics Department, Medical School, University of Athens, 75 Mikras Asias, 115 27, Athens, Greece



View larger version (25K):

[in a new window]
 
Figure 1. The Hurter and Driffield (H&D) curves (optical density vs log relative exposure) under different processing conditions: (a) MR5-II (Agfa), (b) HT (Agfa), (c) HDR (Agfa), (d) MinR-M (Kodak), (e) MinR-2000 (Kodak), (f) AD-M (Fuji), (g) Konica (CM-H). The optical densities (ODs) of the 21 steps of the sensitometric strips correspond to log relative exposure values (LogE) that range from 0 to 3, in steps of 0.15 each. In these figures only the ODs for LogE=>ge;0.9 (steps 7 to 21) are presented in order to enhance the visibility of the differences in the linear part and the shoulder of the H&D curves.

 


View larger version (24K):

[in a new window]
 
Figure 2. The variation of the sensitometric parameters with processing conditions: (a) maximum optical density (ODmax), (b) average gradient (AG), (c) film speed. (The details of processing conditions for each code are given in Table 1Go).

 


View larger version (27K):

[in a new window]
 
Figure 3. The Hurter and Driffield (H&D) curves of all films under the processing assigned with the code B (the details of processing conditions are given in Table 1Go).

 