BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH

Published online before print June 8, 2009
British Journal of Radiology 2009, doi:10.1259/bjr/96908158
This Article
Right arrow Full Text (Rapid PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by HILL, L E
Right arrow Articles by MURCHISON, J T
PubMed
Right arrow PubMed Citation
Right arrow Articles by HILL, L E
Right arrow Articles by MURCHISON, J T
© 2009 The British Institute of Radiology

SHORT COMMUNICATION

Comparison between conventional interrupted high-resolution CT and volume multidetector CT acquisition in the assessment of bronchiectasis

L E HILL 1, G RITCHIE 1, A J WIGHTMAN 1, A T HILL 2, J T MURCHISON 1

1 Department of Radiology, Royal Infirmary of Edinburgh, 51 Little France Crescent, Old Dalkeith Rd, Edinburgh EH16 4SA, UK
2 Department of Respiratory Medicine, Royal Infirmary of Edinburgh, 51 Little France Crescent, Old Dalkeith Rd, Edinburgh EH16 4SA, UK


   Abstract

The aim of this study was to determine whether there is superior diagnostic accuracy for the detection and exclusion of bronchiectasis using 16-slice CT of the chest (1 mm) compared with conventional high-resolution CT (HRCT) of the chest (10 mm). A prospective study was carried out in patients who were referred for chest CT by a chest physician for the investigation of bronchiectasis over a 1-year period. All scans were performed using a 16-slice CT scanner. In addition to contiguous 1 mm slices, conventional HRCT images (1 mm slice every 10 mm) were prepared. Both datasets were dual read. There were 53 patients with a median age of 62 years (range, 51.5–71.5 years), comprising 14 males and 39 females. 10 of 53 scans had no bronchiectasis in either dataset. 36 patients had bronchiectasis diagnosed on both HRCT and 1 mm scans. Two patients had tubular bronchiectasis on the HRCT scans, which was not confirmed on the 1 mm scans. Five patients had confirmed tubular bronchiectasis on the 1 mm scans, which was not identified on HRCT scans. 40 extra lobes demonstrated bronchiectasis on the 1 mm vs the HRCT scans; of these, half were labelled as definite bronchiectasis on the 1 mm scan. There was a 32% increased confidence with the 1 mm scans compared with conventional HRCT of the chest in the diagnosis of bronchiectasis (p < 0.001). In conclusion, there is improved diagnostic accuracy and confidence for diagnosis and exclusion of bronchiectasis using 16-slice chest CT (1 mm cuts) compared with conventional HRCT of the chest.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2009 by the British Institute of Radiology.