BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

First published online October 13, 2008
British Journal of Radiology (2009) 82, 1-12
© 2009 British Institute of Radiology
doi: 10.1259/bjr/12568539

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by HART, D
Right arrow Articles by WALL, B F
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by HART, D
Right arrow Articles by WALL, B F
British Journal of Radiology 82 (2009),1-12 ©2009 The British Institute of Radiology

National reference doses for common radiographic, fluoroscopic and dental X-ray examinations in the UK

D HART, PhD M C HILLIER and B F WALL, BSc

Radiation Protection Division, Health Protection Agency, Chilton, Didcot, Oxon OX11 0RQ, UK

Correspondence: D Hart, Radiation Protection Division, Health Protection Agency, Chilton, Didcot, Oxon OX11 0RQ, UK. E-mail: david.hart{at}hpa.org.uk

The National Patient Dose Database (NPDD) is maintained by the Radiation Protection Division of the Health Protection Agency. The latest review of the database analysed the data collected from 316 hospitals over a 5-year period to the end of 2005. The information supplied amounted to a total of 23 000 entrance surface dose measurements and 57 000 dose–area product measurements for single radiographs, and 208 000 dose–area product measurements along with 187 000 fluoroscopy times for diagnostic examinations or interventional procedures. In addition, patient dose data for dental X-ray examinations were included for the first time in the series of 5-yearly reviews. This article presents a summary of a key output from the NPDD — national reference doses. These are based on the third quartile values of the dose distributions for 30 types of diagnostic X-ray examination and 8 types of interventional procedure on adults, and for 4 types of X-ray examination on children. The reference doses are approximately 16% lower than the corresponding values in the previous (2000) review, and are typically less than half the values of the original UK national reference doses that were derived from a survey in the mid-1980s. This commentary suggests that two of the national reference doses from the 2000 review be retained as diagnostic reference levels because the older sample size was larger than for the 2005 review. No clear evidence could be found for the use of digital imaging equipment having a significant effect on dose.




This article has been cited by other articles:


Home page
RadiologyHome page
D. L. Miller, D. Kwon, and G. H. Bonavia
Reference Levels for Patient Radiation Doses in Interventional Radiology: Proposed Initial Values for U.S. Practice
Radiology, September 29, 2009; (2009) radiol.2533090354v1.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2009 by the British Institute of Radiology.