BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2008) 81, 219-231
© 2008 British Institute of Radiology
doi: 10.1259/bjr/16470646

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by ROBSON, K J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by ROBSON, K J

Full paper

An investigation into the effects of suboptimal viewing conditions in screen-film mammography

K J ROBSON, BSC, PhD

Regional Medical Physics Department, Newcastle General Hospital, Westgate Road, Newcastle upon Tyne, NE4 6BE, UK

Correspondence: K J Robson, Regional Medical Physics Department, Newcastle General Hospital, Westgate Road, Newcastle upon Tyne, NE4 6BE, UK. E-mail: kevin.robson{at}nuth.nhs.uk

The ability of an observer to detect objects on a radiograph is influenced by the conditions under which the image is viewed. Therefore, to ensure that as much diagnostically relevant information as possible can be extracted from the image, it is important that satisfactory viewing conditions for the task are established and maintained. Factors that are thought to be important are the luminance of the image, glare and ambient light. Together, these factors lead to the formation of reflection on the image, which may degrade the observer's performance. The purpose of this study was to explore, in a systematic manner, the effect of the factors outlined above on the performance of an observer conducting a threshold contrast–detail diameter test. Each factor was investigated separately with attempts made to minimize the confounding effects of other factors. When examined individually, viewing box luminance, ambient light and glare were found to have little effect on the contrast–detail performance of the observers. Reflection was found to have a significant effect, particularly non-uniform reflection, and the magnitude of the effect was related to the contrast degradation factor and reflection modulation. These quantities, which are derived from basic photometric measurements, may be used to develop a protocol to assess viewing conditions in screen-film mammography.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2008 by the British Institute of Radiology.