BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2007) 80, 657-667
© 2007 British Institute of Radiology
doi: 10.1259/bjr/97260522

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fujii, K
Right arrow Articles by Kawaura, C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fujii, K
Right arrow Articles by Kawaura, C

Full paper

Comparative evaluation of organ and effective doses for paediatric patients with those for adults in chest and abdominal CT examinations

K Fujii, MSc T Aoyama, PhD S Koyama, PhD and C Kawaura, PhD

Graduate School of Medicine, Nagoya University, Daikominami, Higashi-ku, Nagoya, Japan

Correspondence: K Fujii, Graduate School of Medicine, Nagoya University, Daikominami, Higashi-ku, Nagoya, Japan. E-mail: fujiikei{at}nirs.go.jp

Patient doses in paediatric and adult CT examinations were investigated for modern multislice CT scanners by using specially constructed in-phantom dose measuring systems. The systems were composed of 32 photodiode dosemeters embedded in various tissue and organ sites within anthropomorphic phantoms representing the bodies of 6-year-old children and adults. Organ and the effective doses were evaluated from dose values measured at these sites. In chest CT examinations, organ doses for organs within the scanning area were 2–21 mGy for children and 7–26 mGy for adults. Thyroid doses for children were frequently the highest with a maximum of 21 mGy. In abdominal CT examinations, organ doses for organs within the scanning area were 3–16 mGy for children and 10–34 mGy for adults. Effective doses evaluated for children and adults were found to be proportional to the effective mAs of CT scanners, where linear coefficients were specific to the types of CT examinations and to the manufacturers of CT scanners. Effective doses in paediatric chest CT and abdominal CT examinations were lower than those in adult examinations by a factor of two or greater on average for the same CT scanners because of the lower effective mAs adopted in paediatric examinations.




This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
C. Yamauchi-Kawaura, K. Fujii, T. Aoyama, M. Yamauchi, and S. Koyama
Evaluation of radiation doses from MDCT-imaging in otolaryngology
Radiat Prot Dosimetry, August 1, 2009; 136(1): 38 - 44.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. Huang, M. W.-M. Law, H. K.-F. Mak, S. P.-F. Kwok, and P.-L. Khong
Pediatric 64-MDCT Coronary Angiography With ECG-Modulated Tube Current: Radiation Dose and Cancer Risk
Am. J. Roentgenol., August 1, 2009; 193(2): 539 - 544.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
Y HIROFUJI, T AOYAMA, S KOYAMA, C KAWAURA, and K FUJII
Evaluation of patient dose for barium enemas and CT colonography in Japan
Br. J. Radiol., March 1, 2009; 82(975): 219 - 227.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
C. J. Martin
RADIATION DOSIMETRY FOR DIAGNOSTIC MEDICAL EXPOSURES
Radiat Prot Dosimetry, March 28, 2008; (2008) ncm495v1.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2007 by the British Institute of Radiology.