BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2007) 80, 452-459
© 2007 British Institute of Radiology
doi: 10.1259/bjr/60918774

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kiljunen, T
Right arrow Articles by Savolainen, S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kiljunen, T
Right arrow Articles by Savolainen, S

Full paper

Diagnostic reference levels for thorax X-ray examinations of paediatric patients

T Kiljunen, MSc 1,2 H Järvinen, MSc 1 and S Savolainen, DOC 2,3

1 Radiation Practices Regulation, Radiation and Nuclear Safety Authority, PO Box 14, FI-00881, Helsinki, 2 Department of Physical Sciences, University of Helsinki, PO Box 64, FI-00014, Helsinki, 3 HUS Medical Imaging Center, University of Helsinki, PO Box 340, FI-00029, Helsinki, Finland

Correspondence: Mr Timo Kiljunen, Radiation Practices Regulation, Radiation and Nuclear Safety Authority, Laippatie 4, PO Box 14, Helsinki, FI-00881, Finland. E-mail: timo.kiljunen{at}stuk.fi; timo.kiljunen{at}helsinki.fi

Based on the Medical Exposure Directive of the European Commission, 97/43/Euratom, The Radiation and Nuclear Safety Authority (STUK) in Finland has the responsibility for setting national diagnostic reference levels (DRLs) for the most common radiological examinations. Paediatric patients deserve special attention because of the higher radiation risk compared with adults. The purpose of this paper is to present a method that takes into account patient size when setting DRLs in paediatric patients. The overall data consisted of patient doses collected from six hospitals during the years 1994–2001, and new measurements in two hospitals in 2004. In total, there were 700 chest examinations. The method established by the National Radiological Protection Board (UK) for setting DRLs was not considered feasible in Finnish practice. Patient doses correlated exponentially with the projection thickness, which was measured directly for each patient. Since 1 January 2006, paediatric DRLs for conventional chest examinations have been specified in Finland as a DRL curve by using both dose quantities (entrance surface doses (ESD) and dose–area product (DAP)) as a function of patient projection thickness.




This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
BJR review of the year -- 2007
Br. J. Radiol., April 1, 2008; 81(964): 265 - 269.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2007 by the British Institute of Radiology.