BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

First published online September 27, 2006
British Journal of Radiology (2007) 80, 307-320
© 2007 British Institute of Radiology
doi: 10.1259/bjr/52670770

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mills, R J
Right arrow Articles by Smith, E T S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mills, R J
Right arrow Articles by Smith, E T S

Full paper

3D MRI in multiple sclerosis: a study of three sequences at 3 T

R J Mills, MRCP 1 C A Young, FRCP 1 and E T S Smith, FRCP 2

Departments of 1 Neurology and 2 Neuroradiology, The Walton Centre for Neurology and Neurosurgery, Liverpool, UK

Correspondence: Dr Roger J Mills, Neurology, Walton Centre for Neurology and Neurosurgery, Lower Lane, Fazakerley, Liverpool L9 7LJ, UK. E-mail: rjm{at}crazydiamond.co.uk

The objective of this study was to assess the feasibility of using 3D acquisition at 3 T for imaging patients with multiple sclerosis (MS). Feasibility was assessed by three criteria based on acquisition time, specific absorption rate (SAR) and image quality. 47 patients with clinically definite MS underwent imaging in a Siemens 3T Trio MR scanner. Patient safety data were obtained following the scan sessions. The study had local ethics approval. The following three-dimensional (3D) sequences, all acquired coronally, were used: T2 fluid attenuated inversion recovery (FLAIR) (repetition time (TR) 6000 ms, echo time (TE) 353 ms, inversion time (TI) 2200 ms), 0.5x0.5x1 mm voxels, acquisition time 10 min 38 s; T2 turbo spin echo (TSE) (TR 3000 ms, TE 354 ms), 1x1x1 mm voxels, acquisition time 8 min 29 s; T1 inversion recovery (IR) (TR 2040 ms, TE 5.56 ms, TI 1100 ms), matrix 512x448 (0.5x0.5 mm pixels), 0.5x0.5x1 mm voxels, acquisition time 7 min 38 s. Total acquisition time was 26 min 45 s. Example images are presented. 3D scanning at 3 T provides highly detailed, high quality images with acquisition times tolerated by MS patients, even by those with severe disability. The volumetric data are suitable for a wide variety of post-processing techniques; the authors suggest that 3D studies at 3 T should be considered as the possible brain imaging protocol for either cross-sectional or longitudinal studies in MS and that the 3D T2 FLAIR sequence should be considered for the purposes of radiological diagnosis.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2007 by the British Institute of Radiology.