BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

First published online November 22, 2006
British Journal of Radiology (2007) 80, 279-283
© 2007 British Institute of Radiology
doi: 10.1259/bjr/54321311

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mangar, S
Right arrow Articles by Khoo, V
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mangar, S
Right arrow Articles by Khoo, V

Short communication

A feasibility study of using gold seeds as fiducial markers for bladder localization during radical radiotherapy

S Mangar, MRCP, FRCR1, A Thompson, FRCS1, E Miles, MRCP, FRCR, PhD2, R Huddart, MRCP, FRCR, PhD1, A Horwich, FRCP, FRCR, PhD1 and V Khoo, FRACR, FRCR, PhD1

1 Academic Department of Urology, 2 Radiotherapy Department, Royal Marsden Hospital and Institute of Cancer Research, London, UK

Correspondence: Dr Vincent Khoo, Consultant Clinical Oncologist, Academic Urology Unit, The Royal Marsden NHS Trust, Fulham Road, London SW3 6JJ, UK. E-mail: Vincent.Khoo{at}rmh.nhs.uk

Target localization and verification of the treatment position is important for the accurate delivery of conformal radiotherapy. The bladder in particular is a deformable structure whose shape and position continually varies throughout a course of radiation treatment as a result of bladder filling. We report a novel technique of organ localization using gold seeds as fiducial markers that are implanted into the bladder using a specially adapted applicator that is passed through a rigid cystoscope. The seeds are readily apparent on electronic portal imaging taken at the time of radiotherapy and can thus act as a surrogate for bladder position. The feasibility and technical aspects of performing such a procedure on eight patients were assessed. In all of the patients, some of the seeds were visible on the planning CT scan and remained within the bladder wall throughout the course of radiotherapy treatment. The drop-out rate was minimized by the use of cystodiathermy at the site of seed insertion. It was possible to place the seeds in both areas of normal and diseased bladder tissue. The procedure was associated with minimal toxicity. This technique will form the basis for planning further studies on bladder localization.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2007 by the British Institute of Radiology.