BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

First published online October 12, 2006
British Journal of Radiology (2007) 80, 248-255
© 2007 British Institute of Radiology
doi: 10.1259/bjr/52356535

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Van Der Molen, A J
Right arrow Articles by Geleijns, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Van Der Molen, A J
Right arrow Articles by Geleijns, J

Full Paper

16-slice CT: achievable effective doses of common protocols in comparison with recent CT dose surveys

A J Van Der Molen, MD, W J H Veldkamp, PhD and J Geleijns, PhD

Department of Radiology C-2S, Leiden University Medical Center, Albinusdreef 2, NL-2333 ZA Leiden, The Netherlands

Correspondence: A J van der Molen. E-mail: molen{at}lumc.nl

The aim of the study was to investigate achievable dose levels in 16-slice CT by evaluating CT dose indices (CTDI) and effective doses of dose-optimized protocols compared with 4-slice dose surveys. Normalized CTDI free in air and in 16 cm and 32 cm diameter phantoms were measured on four different 16-slice CT scanners in the Netherlands. All collimation and tube potential settings were analysed. Volume CTDI was calculated for adult protocols for brain, chest, pulmonary angiography (CTPA), abdomen and biphasic liver CT. Effective doses were calculated first using volume CTDI with conversion factors and second from CTDIair values using the ImPACT dose calculator. Average results of the 16-slice scanners were correlated to results of dose surveys with predominantly 4-slice scanners. Statistical analysis was done with Student t-tests with a Bonferroni correction; therefore p < 0.017 was significant. The results of CTDIair and weighted CTDI were documented for all scanners. Effective doses averaged over four scanners for brain, chest, CTPA, abdomen and biphasic liver protocols were 1.9±0.4, 3.8±0.4, 3.0±0.2, 7.2±0.9 and 10.2±1.3 mSv, respectively. Compared with dose surveys achievable effective doses were equal (p = 0.069) to significantly lower (p < 0.017) for chest and abdomen protocols. For 16-slice spiral brain CT there was a trend of equal doses compared with sequential brain CT in the dose surveys. Thus, with dose-optimized protocols 16-slice CT can achieve equal to lower effective doses in examinations of the chest and abdomen compared with 4-slice CT, while doses can remain stable in the brain.