BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

First published online October 12, 2006
British Journal of Radiology (2007) 80, 231-234
© 2007 British Institute of Radiology
doi: 10.1259/bjr/60407135

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tatsugami, F
Right arrow Articles by Narabayashi, I
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tatsugami, F
Right arrow Articles by Narabayashi, I

Full paper

Usefulness of saline pushing in reduction of contrast material dose in abdominal CT: evaluation of time–density curve for the aorta, portal vein and liver

F Tatsugami, MD, M Matsuki, MD, Y Inada, MD, G Nakai, MD, M Tanikake, MD, S Yoshikawa, RT and I Narabayashi, MD

Department of Radiology, Osaka Medical College, 2-7 Daigaku-machi, Takatsuki City, Osaka 569-8686, Japan

Correspondence: Fuminari Tatsugami, MD, Department of Radiology, Osaka Medical College, 2-7 Daigaku-machi, Takatsuki City, Osaka 569-8686, Japan. E-mail: sa104{at}rg8.50-net.ne.jp

The effects of saline pushing after contrast material injection were investigated as well as the possibility for this technique to reduce contrast material doses in liver CT examinations. 52 patients were divided randomly into three groups: 100 ml of contrast material (300 mg I ml–1) only (A; n = 19), 100 ml of contrast material pushed with 50 ml of saline solution (B; n = 17), and 85 ml of contrast material pushed with 50 ml of saline solution (C; n = 16). Single-level images were obtained at the level of the main portal vein after the initiation of contrast material injection. There were no significant differences in the mean peak enhancement values (PE) and the mean time to peak enhancement values (TPE) of the aorta between the three groups. The mean PE of the portal vein in group B increased 21 HU over that in group A (p<0.05), and there was no significant difference between groups A and C. The mean PE of the liver in group B increased 7 HU over that in group A (p<0.05), and there was no significant difference between groups A and C. The mean TPE of the portal vein was shorter by 4 s (p<0.05), and that of the liver was shorter by 5 s (p<0.05) in group C compared with those in group A. In conclusion, saline pushing increases the enhancement values of the portal vein and liver, and allows a contrast material dose reduction of 15 ml without decreasing hepatic and vascular enhancement at adequate scan timing.