BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

First published online September 27, 2006
British Journal of Radiology (2007) 80, 126-131
© 2007 British Institute of Radiology
doi: 10.1259/bjr/32367104

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Patel, I
Right arrow Articles by Kirby, M C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Patel, I
Right arrow Articles by Kirby, M C

Short communication

Design and implementation of an electronic data recording and processing system for physics quality control checks in external beam radiotherapy

I Patel, MSc, CSci, MIPEM and M C Kirby, PhD, CSci, MIPEM

North Western Medical Physics, Radiotherapy Department, Rosemere Cancer Centre, Royal Preston Hospital, Preston PR2 9HT, UK

Correspondence: Mr Imran Patel, North Western Medical Physics, Radiotherapy Department, Rosemere Cancer Centre, Royal Preston Hospital, Preston PR2 9HT, UK. E-mail: imran.patel{at}lthtr.nhs.uk

Quality control (QC) of external beam radiotherapy equipment ensures that commissioning performance is maintained. Paper based data recording is still used for QC, but this is resource intensive in terms of data calculation and processing. Electronic systems of data recording have many advantages; for example, they facilitate the analysis of data on a regular basis, allowing the user to examine the "health" of each machine; they help review and audit local frequencies of each check and can possibly predict component failure. They also allow for secure calculation of results and automatic charting for routine trend analysis. Initially, data recording at our centre was paper-based for daily, weekly and monthly checks. This paper system has been successfully replaced with an electronic system for QC data recording and processing for linear accelerators and superficial units. The system makes use of personal digital assistants and networked laptops for online recording of data, and networked desktop PCs for offline work. The systems of data recording have been designed using the power of macros within Microsoft Excel, which automatically calculate each QC parameter and charts the data recorded for long-term analysis of trends. As of the beginning of 2006, these systems have been fully implemented. The benefits of implementing such a system are numerous, for example, central storage, backup and archiving of data, for greater security and reducing operator errors in calculations. Other benefits are discussed within the paper. In the future, we hope to develop similar systems of data recording for QC checks on other radiotherapy equipment.