Recent radiobiological studies have provided compelling evidence that the low energy X-rays as used in mammography are approximately four times but possibly as much as six times more effective in causing mutational damage than higher energy X-rays. Since current radiation risk estimates are based on the effects of high energy gamma radiation, this implies that the risks of radiation-induced breast cancers for mammography X-rays are underestimated by the same factor. The balance of risk and benefit for breast screening have been re-analysed for relative biological effectiveness (RBE) values between 1 and 6 for mammography X-rays. Also considered in the analysis is a change in the dose and dose-rate effectiveness factor (DDREF) from 2 to 1, women with larger than average breasts and implications for women with a family history of breast cancer. A potential increase in RBE to 6 and the adoption of a DDREF of unity does not have any impact on the breast screening programme for women aged 5070 years screened on a 3 yearly basis. Situations for which breast screening is not justified due to the potential cancers induced relative to those detected (the detection-to-induction ratio (DIR)) are given for a range of RBE and DDREF values. It is concluded that great caution is needed if a programme of early regular screening with X-rays is to be used for women with a family history of breast cancer since DIR values are below 10 (the lowest value considered acceptable for women below 40 years) even for modest increases in the RBE for mammography X-rays.
This article has been cited by other articles:
![]() |
D. A. Kennedy, T. Lee, and D. Seely A Comparative Review of Thermography as a Breast Cancer Screening Technique Integr Cancer Ther, March 1, 2009; 8(1): 9 - 16. [Abstract] [PDF] |
||||
![]() |
BJR review of the year - 2006 Br. J. Radiol., March 1, 2007; 80(951): 147 - 151. [Full Text] [PDF] |
||||
![]() |
B M Moores Relative biological effectiveness and exposure of the female breast Br. J. Radiol., February 1, 2007; 80(950): 141 - 142. [Full Text] [PDF] |
||||
![]() |
G J Heyes, A J Mill, and M W Charles Authors' reply Br. J. Radiol., October 1, 2006; 79(946): 852 - 854. [Full Text] [PDF] |
||||
![]() |
J L Redpath and R E J Mitchel Enhanced biological effectiveness of low energy X-rays and implications for the UK breast screening programme. Br. J. Radiol., October 1, 2006; 79(946): 854 - 855. [Full Text] [PDF] |
||||
![]() |
J Law, K Faulkner, and K C Young RBE for mammographic X-ray energies. Br. J. Radiol., October 1, 2006; 79(946): 851 - 852. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| BJR | DMFR | IMAGING | ALL BIR JOURNALS |