BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2005) 78, 1086-1094
© 2005 British Institute of Radiology
doi: 10.1259/bjr/36348588

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cash, C J C
Right arrow Articles by Gee, A H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cash, C J C
Right arrow Articles by Gee, A H

Short communication

Spatial mapping of the brachial plexus using three-dimensional ultrasound

C J C Cash, MRCP, FRCR1, A M Sardesai, MD, DA, FRCA2, L H Berman, MRCP, FRCR1, M J Herrick, FRCA2, G M Treece, MA, PhD3, R W Prager, MA, PhD3 and A H Gee, MA, PhD3

Cambridge University Departments of 1 Radiology and 2 Anaesthesia, Addenbrookes Hospital NHS Trust, Hills Road, Cambridge CB2 2QQ and 3 Cambridge University Department of Engineering, Trumpington Street, Cambridge CB2 1PZ, UK

Imaging of the brachial plexus with MRI and standard two-dimensional (2D) ultrasound has been reported, and 2D ultrasound-guided regional anaesthetic block is an established technique. The aim of this study was to map the orientation of the brachial plexus in relation to the first rib, carotid and subclavian arteries, using three-dimensional (3D) ultrasound. A free-hand optically tracked 3D ultrasound system was used with a 12 MHz transducer. 10 healthy volunteers underwent 3D ultrasound of the neck. From the 3D ultrasound data sets, the outlines of the brachial plexus, subclavian artery and first rib were manually segmented. A surface was interpolated from the series of outlines to produce a spatially orientated 3D reconstruction of the brachial plexus. The brachial plexus could be mapped in all volunteers, although a variation in image resolution between individuals existed. Anatomical variations were demonstrated between the 10 volunteers; the most notable and clinically relevant was the alignment of the plexus divisions. 3D reconstructions illustrated the plexus, changing its orientation from a vertical alignment in the interscalene region to a more horizontal alignment in the supraclavicular fossa. Spatial mapping of the brachial plexus is possible with 3D ultrasound using the subclavian artery and first rib as landmarks. There is a deviation from the conventionally described anatomy and this may have implications for the administration of regional anaesthesia.




This article has been cited by other articles:


Home page
Br J AnaesthHome page
P. M. Hopkins
Ultrasound guidance as a gold standard in regional anaesthesia
Br. J. Anaesth., March 1, 2007; 98(3): 299 - 301.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2005 by the British Institute of Radiology.