BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2005) 78, 737-741
© 2005 British Institute of Radiology
doi: 10.1259/bjr/97956788

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Henry, A M
Right arrow Articles by Khoo, V S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Henry, A M
Right arrow Articles by Khoo, V S

Full Paper

An assessment of clinically optimal gold marker length and diameter for pelvic radiotherapy verification using an amorphous silicon flat panel electronic portal imaging device

A M Henry, FRCR 1 J Stratford, DCR(T) 1 J Davies, DCR(T) 1 C McCarthy, BSc 1 R Swindell, MSc 2 J Sykes, MSc 3 C J Moore, PhD 3 P Price, FRCR 1 and V S Khoo, FRACR 1

1 Academic Department of Radiation Oncology, University of Manchester, 2 Department of Medical Statistics and 3 Northwest Medical Physics, Christie Hospital NHS Trust, Wilmslow Road, Manchester M20 4BX, UK

Correspondence: Dr Ann Henry, Clinical Research Fellow, Academic Department of Radiation Oncology, Christie Hospital, Wilmslow Road, Manchester M20 4BX, UK

Verification of target organ position is essential for the accurate delivery of conformal radiotherapy. Megavoltage electronic portal imaging with flat panel amorphous silicon detectors delivers high quality images that can be used for verification of bony landmark position. Gold markers implanted into the target organ can be visualized and used as a surrogate of actual organ position. On-line compensation for marker displacement, by adjusting patient position, can reduce geometric errors associated with radiation delivery. This study assesses the optimal marker length and diameter to be used with an amorphous silicon (a-Si) flat panel detector and electronic portal images (EPIs), prior to implementation of a clinical programme of gold marker insertion in prostate cancer patients. Seven marker sizes varying from 3 mm to 8 mm in length and 0.8 mm to 1.1 mm in diameter were investigated in a group of patients undergoing pelvic radiotherapy using an 8 MV Elekta SL20 linear accelerator. Markers were placed on the skin entry and exit sites of the treatment beam and EPIs in both lateral and anterior pelvic views were acquired. Three observers independently assessed visibility success and failure using a subjective scoring system. Markers less than 5 mm in length or 0.9 mm in diameter were poorly visualized (<70% visualization success in lateral EPIs). The marker measuring 0.9 mm x 5 mm appears to be clinically optimal in pelvic radiotherapy patients (80% visualization success in lateral EPIs) and will be used for actual organ implantation.




This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
S Mangar, A Thompson, E Miles, R Huddart, A Horwich, and V Khoo
A feasibility study of using gold seeds as fiducial markers for bladder localization during radical radiotherapy
Br. J. Radiol., April 1, 2007; 80(952): 279 - 283.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
M C Kirby and A G Glendinning
Developments in electronic portal imaging systems
Br. J. Radiol., September 1, 2006; 79(Special_Issue_1): S50 - S65.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
J Kinsman and P Humphrey
Portal imaging
Br. J. Radiol., August 1, 2005; 78(932): 681 - 682.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2005 by the British Institute of Radiology.