BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2005) 78, 634-636
© 2005 British Institute of Radiology
doi: 10.1259/bjr/28412864

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Charnley, N
Right arrow Articles by Bottomley, D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Charnley, N
Right arrow Articles by Bottomley, D

Short communication

The use of CT-MR image registration to define target volumes in pelvic radiotherapy in the presence of bilateral hip replacements

N Charnley, FRCR 1 A Morgan, BSc MSc 2 E Thomas, FRCR 1 S Wilson 2 S Bacon, MPhys, MSc 2 D Wilson, BSc, MSc 2 and D Bottomley, FRCR 1

1 Radiotherapy Department and 2 Medical Physics Department, Cookridge Hospital, Cookridge, Leeds LS16 6QB, UK

Correspondence: A Morgan

Increasing numbers of patients with hip replacements are presenting for pelvic radiotherapy, which is usually planned using CT images. Image artefacts caused by the presence of metallic implants tend not to be severe for single hip replacements and allow for adequate definition of target volumes. When bilateral hip replacements are present, the image artefacts can render CT images useless for target definition, particularly for tumours of the prostate and bladder. MR images are not susceptible to such severe artefacts. This note describes a small series of patients with bilateral hip replacements on whom CT-MR image registration has been used to successfully define adequate target volumes.




This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
M Aubin, O Morin, J Chen, A Gillis, B Pickett, J F Aubry, C Akazawa, J Speight, M Roach III, and J Pouliot
The use of megavoltage cone-beam CT to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement
Br. J. Radiol., November 1, 2006; 79(947): 918 - 921.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2005 by the British Institute of Radiology.