BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2005) 78, 422-427
© 2005 British Institute of Radiology
doi: 10.1259/bjr/32912696

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Honey, I D
Right arrow Articles by Evans, D S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Honey, I D
Right arrow Articles by Evans, D S

Full Paper

Investigation of optimum energies for chest imaging using film–screen and computed radiography

I D Honey, MSc, A Mackenzie, MSc and D S Evans, MSc

Kings Centre for the Assessment of Radiological Equipment (KCARE), Kings College Hospital, London SE5 9RS, UK

The purpose of the study was to compare the image quality of film–screen (FS) and computed radiography (CR) for adult chest examinations across a range of beam energies. A series of images of the CDRAD threshold contrast detail detection phantom were acquired for a range of tube potential and exposure levels with both CR and FS. The phantom was placed within 9 cm of Perspex to provide attenuation and realistic levels of scatter in the image. Hardcopy images of the phantom were scored from a masked light-box by two scorers. Threshold contrast indices were used to calculate a visibility index (VI). The relationships between dose and image quality for CR and for FS are fundamentally different. The improvements in VIs obtained using CR at 75 kVp and 90 kVp were found to be statistically significant compared with 125 kVp at matched effective dose levels. The relative performance of FS and CR varies as a function of energy owing to the different k-edges of each system. When changing from FS to CR, the use of lower tube potentials may allow image quality to be maintained whilst reducing effective dose. A tube voltage of 90 kVp is indicated by this work, but may require clinical verification.




This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
B M Moores
Relative biological effectiveness and exposure of the female breast
Br. J. Radiol., February 1, 2007; 80(950): 141 - 142.
[Full Text] [PDF]


Home page
ImagingHome page
H Cole and C P Lawinski
Developments in radiography and fluoroscopy
Imaging, June 1, 2006; 18(2): 75 - 81.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2005 by the British Institute of Radiology.