British Journal of Radiology (2005) 78, 219-229
© 2005 British Institute of Radiology
doi: 10.1259/bjr/12209589

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Whitby, M
Right arrow Articles by Martin, C J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Whitby, M
Right arrow Articles by Martin, C J

Full Paper

A study of the distribution of dose across the hands of interventional radiologists and cardiologists

M Whitby, MSc and C J Martin, PhD

Health Physics, Department of Clinical Physics and Bio-Engineering, West House, Gartnavel Royal Hospital, Glasgow, UK

The magnitude and distribution of doses across the hands of interventional radiologists and cardiologists have been studied. The aims were to determine the region of highest dose, investigate variations in dose distribution, and propose an effective method for dose monitoring. Doses have been measured using sets of up to 18 thermoluminescent dosemeters (TLDs) for 183 single procedures. Important factors influencing the dose to the hand are the type of procedure, particularly the access route, the X-ray equipment used, and the experience of the operator. Radiologists performing percutaneous procedures received the highest doses, because of the proximity of their hands to the X-ray tube. The majority of procedures involve a combination of twisting and prodding actions, and the relative proportions of each determine the parts of the fingers which receive a higher dose. For most interventional radiology and cardiology procedures the bases of the ring and little fingers receive the highest dose. However, during percutaneous procedures the tips of the middle and ring fingers could receive doses which were 20–30% higher than this. For radiologists and cardiologists with a mixed workload, monitoring using TLD rings located at the base of the little or the ring fingers on either hand should provide a reasonable estimate of dose to the most exposed area. Monitoring is recommended for operators who may receive over 50 mSv to their hands per year, and should be considered for operators carrying out therapeutic procedures involving patient dose–area products over 500 Gy cm2 per month.




This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
F. Vanhavere, E. Carinou, L. Donadille, M. Ginjaume, J. Jankowski, A. Rimpler, and M. Sans Merce
AN OVERVIEW ON EXTREMITY DOSIMETRY IN MEDICAL APPLICATIONS
Radiat Prot Dosimetry, April 29, 2008; (2008) ncn149v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
P. Covens, D. Berus, N. Buls, P. Clerinx, and F. Vanhavere
PERSONAL DOSE MONITORING IN HOSPITALS: GLOBAL ASSESSMENT, CRITICAL APPLICATIONS AND FUTURE NEEDS
Radiat Prot Dosimetry, October 23, 2007; (2007) ncm418v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
E. Stranden, T. Seske, and A. Widmark
INDICATORS FOR THE FINGER DOSES IN INTERVENTIONAL RADIOLOGY
Radiat Prot Dosimetry, May 24, 2007; (2007) ncm203v1.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
N Hidajat, P Wust, M Kreuschner, R Felix, and R-J Schroder
Radiation risks for the radiologist performing transjugular intrahepatic portosystemic shunt (TIPS).
Br. J. Radiol., June 1, 2006; 79(942): 483 - 486.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2005 by the British Institute of Radiology.