BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2005) 78, 51-54
© 2005 British Institute of Radiology
doi: 10.1259/bjr/29242407

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Orecchia, R
Right arrow Articles by Franzetti, S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Orecchia, R
Right arrow Articles by Franzetti, S

Full Paper

Irradiation with standard tangential breast fields in patients treated with conservative surgery and sentinel node biopsy: using a three-dimensional tool to evaluate the first level coverage of the axillary nodes

R Orecchia, MD 1,4 A Huscher, MD 1 M C Leonardi, MD 1 R Gennari, MD 2 V Galimberti, MD 2 C Garibaldi, PhD 3 E Rondi, PhD 3 L C Bianchi, MD 1 S Zurrida, MD 2 and S Franzetti, MD 1

1 Division of Radiotherapy, 2 Division of Senology, 3 Medical Physic Unit, European Institute of Oncology, Milan and 4 University of Milan, Milan, Italy

Correspondence: Prof. Roberto Orecchia, Division of Radiotherapy, European Institute of Oncology, Via Ripamonti 435, I-20141 Milan, Italy

Recent data show that axillary coverage can be obtained, but only through a selective CT-based treatment planning, as standard tangential fields are inadequate to deliver therapeutic doses. Currently, the replacement of axillary dissection with new techniques, such as sentinel node (SN) biopsy, makes it necessary to re-address the question about the real role of axillary irradiation, complicated by the differences in the anatomy of dissected and undissected axillary regions. The purpose of this paper is the dosimetric analysis of first axillary level coverage in standard irradiation of 15 breast-cancer patients treated with quadrantectomy and SN biopsy (negative finding). During surgery a clip on the site of the SN was positioned, marking the caudal margin of first axillary level. After the breast treatment plan was completed, the first axillary level was contoured on CT scans, from the site of the surgical clip up to the sternal manubrium, for coverage analysis with dose–volume histograms (DVHs) and three-dimensional isodose visualization. The maximum dose mean ranged from 5% to 80% of the prescribed dose (mean value 48.7%). The mean total dose received by the volume of interest was lower than 40 Gy in all but one patient. No patient had total irradiation of first nodal level; only one patient had 35% of the volume enclosed in the 100% isodose. Our analysis lead to the conclusion that therapeutic doses are not really delivered to first level axillary level nodes by a standard tangential field technique, and that specific treatment planning and beam arrangement are required when adequate coverage is necessary.