Patient dose in multislice CT: why is it increasing and does it matter?

P Dawson, PhD, FRCP, FRCR

UCL Hospitals, Mortimer Street, London W1T 3AA, UK

A brief review is presented of the reasons why multislice spiral/helical CT is associated with a higher radiation dose burden to the patient even than incremental CT. These include both intrinsic technological and geometric factors as well as simply a growing use of CT in an increasing number of applications. The typical magnitude of this dose burden is indicated and the basis for the anxiety that underpins it, namely the linear no-threshold (LNT) hypothesis, is discussed, together with the countervailing hypothesis that there is indeed a threshold for radiation harm in man and that the radiation doses associated with CT may lie below this threshold and may even be beneficial (radiation hormesis). There are as yet no certainties in this important area but it is argued that it is not a given that the doses associated with CT are harmful.




This article has been cited by other articles:


Home page
RadiologyHome page
K. Rothkamm, S. Balroop, J. Shekhdar, P. Fernie, and V. Goh
Leukocyte DNA Damage after Multi-Detector Row CT: A Quantitative Biomarker of Low-Level Radiation Exposure
Radiology, January 1, 2007; 242(1): 244 - 251.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
B F Wall, G M Kendall, A A Edwards, S Bouffler, C R Muirhead, and J R Meara
What are the risks from medical X-rays and other low dose radiation?
Br. J. Radiol., April 1, 2006; 79(940): 285 - 294.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
M A Lewis and S Edyvean
Patient dose reduction in CT
Br. J. Radiol., October 1, 2005; 78(934): 880 - 883.
[Full Text] [PDF]