BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2004) 77, 927-930
© 2004 British Institute of Radiology
doi: 10.1259/bjr/32730898

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Livingstone, R S
Right arrow Articles by Raj, D V
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Livingstone, R S
Right arrow Articles by Raj, D V

Full Paper

Evaluation of work practices and radiation dose during adult micturating cystourethrography examinations performed using a digital imaging system

R S Livingstone, MSc, C G Koshy, MBBS and D V Raj, PhD

Department of Radiodiagnosis, Christian Medical College, Vellore 632004, India

A micturating cystourethrography (MCU) examination is a specific radiological procedure that is performed under fluoroscopic screening to visualize the bladder by filling it with contrast material and to evaluate the urethral morphology during voiding. It is necessary to evaluate radiation dose during MCU examination since it involves radiosensitive organs such as the gonads. Radiation dose imparted to 109 patients undergoing MCU examination were measured using a dose–area product (DAP) meter. Patients were categorized into two groups based on whether filling of the bladder with contrast medium was done retrogradely (MCU) or by the suprapubic percutaneous route (SP-MCU). The DAP values to Group A (MCU) and Group B (SP-MCU) patients varied from 0.43 Gycm2 to 9.26 Gycm2 and 0.54 Gycm2 to 9.87 Gycm2, respectively. Reduction of radiation dose to patients was possible by the use of optimized exposure factors, precise collimation of X-ray beam, use of 0.2 mm copper filters and by acquiring images digitally.




This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
G Compagnone, M C. Baleni, L Pagan, F L Calzolaio, L Barozzi, and C Bergamini
Comparison of radiation doses to patients undergoing standard radiographic examinations with conventional screen-film radiography, computed radiography and direct digital radiography.
Br. J. Radiol., November 1, 2006; 79(947): 899 - 904.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
J Eaton and J Richenberg
Imaging of the urethra: current status
Imaging, October 1, 2005; 17(2): 139 - 149.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2004 by the British Institute of Radiology.