BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2004) 77, 675-678
© 2004 British Institute of Radiology
doi: 10.1259/bjr/72726487

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kotre, C J
Right arrow Articles by Guibelalde, E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kotre, C J
Right arrow Articles by Guibelalde, E

Short communication

Optimization of variable temporal averaging in digital fluoroscopy

C J Kotre, PhD1 and E Guibelalde, PhD2

1 Regional Medical Physics Department, Newcastle General Hospital, Newcastle-upon-Tyne NE4 6BE, UK and 2 Department of Radiology (Medical Physics), School of Medicine, Complutense University of Madrid, 28040 Madrid, Spain

In modern X-ray fluoroscopy systems, the amount of temporal averaging (i.e. persistence) applied to the image is often user selectable. The objective of this work is to quantify the effect of variable temporal averaging on the detection of low contrast test objects moving at a range of known speeds within the digital fluoroscopic image. An image intensifier system with a short-persistence television camera was used to record image sequences of a moving threshold contrast-detail diameter test object onto broadcast-standard U-matic videotape. The image sequences were replayed through an image processing system allowing different amounts of temporal averaging to be applied. The test images were scored by an experienced observer. The temporal averaging time constants produced by the added image processing were measured using a method based on noise correlation. Results are presented showing the trends of threshold contrast with test detail diameter and movement speed. The optimum value of temporal averaging time constant is presented as a function of detail diameter for a range of speeds. By comparison with the limited information available in the literature on organ movement, it is tentatively concluded that for the organ movement speeds expected in the abdomen, the optimum imaging system persistence time constant should be approximately 0.15 s. For the much greater speeds associated with cardiac motion no additional frame averaging, i.e. just the persistence provided by the observer's visual system, appears to be optimal.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2004 by the British Institute of Radiology.