BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2004) 77, 395-404
© 2004 British Institute of Radiology
doi: 10.1259/bjr/32514512

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Terini, R A
Right arrow Articles by Herdade, S B
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Terini, R A
Right arrow Articles by Herdade, S B

Full Paper

Comprehensive analysis of the spectrometric determination of voltage applied to X-ray tubes in the radiography and mammography energy ranges using a silicon PIN photodiode

R A Terini, PhD 1,2 M A G Pereira, BSc 1 R Künzel, MSc 1,3 P R Costa, PhD 1 and S B Herdade, PhD 1

1 Serviço Técnico de Aplicações Médico-Hospitalares, Instituto de Eletrotécnica e Energia, Universidade de São Paulo, Av. Prof. Luciano Gualberto, 1289, Cidade Universitária, CEP. 05508-010, São Paulo, SP, 2 Departamento de Física, Pontifícia Universidade Católica de São Paulo, R. Marquês de Paranaguá, 111, Consolação, CEP. 01303-050, São Paulo, SP and 3 Instituto de Física, Universidade de São Paulo, R. do Matão, Travessa R, 187, Cidade Universitária, CEP. 05508-900, São Paulo, SP, Brazil

This work describes the analysis of factors which affect the results of estimation of the electron accelerating potential (kVp) applied to an X-ray tube, through determination of the end point of the energy spectrum of the emitted radiation beam. Measurements have been performed utilizing two spectrometers each with a silicon PIN photodiode: one operating at room temperature, and the other, a high resolution spectrometer, with a Peltier cooler. Both were directly irradiated by different X-ray beams. Both systems work at low voltage and without liquid nitrogen cooling, thus avoiding the drawbacks presented by germanium detectors. Each kVp value was determined by linear regression of the end of the spectrum, so as to give, simultaneously, the best fit to the experimental data and low standard deviation for the kVp value. Detector energy resolution and calibration, counting statistics and high voltage waveform ripple have been investigated in order to establish better experimental conditions and to optimize measurement time. Results of measurements carried out with X-ray tubes connected to single-phase, three-phase or constant potential units, using additional filtration of Cu, Al or Mo (for mammographic beams), are presented. The variations resulted in kVp uncertainties up to 0.1 kV.