BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2004) 77, 323-328
© 2004 British Institute of Radiology
doi: 10.1259/bjr/78576048

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Britten, A J
Right arrow Articles by Adam, E J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Britten, A J
Right arrow Articles by Adam, E J

Full Paper

The addition of computer simulated noise to investigate radiation dose and image quality in images with spatial correlation of statistical noise: an example application to X-ray CT of the brain

A J Britten, PhD, M Crotty, MSc, H Kiremidjian, MSc, A Grundy, FRCR and E J Adam, MRCP, FRCR

Departments of Medical Physics and Diagnostic Radiology, St George's Healthcare NHS Trust, London SW17 0QT, UK

This study validates a method to add spatially correlated statistical noise to an image, applied to transaxial X-ray CT images of the head to simulate exposure reduction by up to 50%. 23 patients undergoing routine head CT had three additional slices acquired for validation purposes, two at the same clinical 420 mAs exposure and one at 300 mAs. Images at the level of the cerebrospinal fluid filled ventricles gave readings of noise from a single image, with subtraction of image pairs to obtain noise readings from non-uniform tissue regions. The spatial correlation of the noise was determined and added to the acquired 420 mAs image to simulate images at 340 mAs, 300 mAs, 260 mAs and 210 mAs. Two radiologists assessed the images, finding little difference between the 300 mAs simulated and acquired images. The presence of periventricular low density lesions (PVLD) was used as an example of the effect of simulated dose reduction on diagnostic accuracy, and visualization of the internal capsule was used as a measure of image quality. Diagnostic accuracy for the diagnosis of PVLD did not fall significantly even down to 210 mAs, though visualization of the internal capsule was poorer at lower exposure. Further work is needed to investigate means of measuring statistical noise without the need for uniform tissue areas, or image pairs. This technique has been shown to allow sufficiently accurate simulation of dose reduction and image quality degradation, even when the statistical noise is spatially correlated.




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
T. Kubo, P.-J. P. Lin, W. Stiller, M. Takahashi, H.-U. Kauczor, Y. Ohno, and H. Hatabu
Radiation Dose Reduction in Chest CT: A Review
Am. J. Roentgenol., February 1, 2008; 190(2): 335 - 343.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. R. Fefferman, E. Bomsztyk, A. M. Yim, R. Rivera, J. B. Amodio, L. P. Pinkney, N. A. Strubel, M. E. Noz, and H. Rusinek
Appendicitis in Children: Low-Dose CT with a Phantom-based Simulation Technique--Initial Observations
Radiology, November 1, 2005; 237(2): 641 - 646.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
M A Lewis and S Edyvean
Patient dose reduction in CT
Br. J. Radiol., October 1, 2005; 78(934): 880 - 883.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2004 by the British Institute of Radiology.