BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2004) 77, 224-230
© 2004 British Institute of Radiology
doi: 10.1259/bjr/32409995

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meyer, P
Right arrow Articles by Siffert, P
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meyer, P
Right arrow Articles by Siffert, P

Full Paper

Evaluation of the use of six diagnostic X-ray spectra computer codes

P Meyer, PhD 1 E Buffard, MS 1 L Mertz, PhD 2 C Kennel A Constantinesco, PhD 2 and P Siffert, PhD 1

1 Laboratoire PHASE/CNRS, 23 rue du Loess, BP 20, 67037 Strasbourg Cedex and 2 Laboratoire de Biophysique et Médecine Nucléaire, CHU Hautepierre, Avenue Molière, 67000 Strasbourg, France

A knowledge of photon energy spectra emitted from X-ray tubes in radiology is crucial for many research domains in the medical field. Since spectrometry is difficult because of high photon fluence rates, a convenient solution is to use computational models. This paper describes the use of six computer codes based on semiempirical or empirical models. The use of the codes was assessed, notably by comparing theoretical half value layers and air kerma with measurements on five different X-ray tubes used in a research hospital. It was found that three out of the six computer codes give relative spectra very close to those produced by X-ray units equipped with constant potential generators: the mean difference between measured and modelled half value layer was less than 3% with a standard deviation of 3.6% whatever the tube and the applied voltage. Absolute output is less accurate: for four computer codes, the mean difference between the measured and modelled air kerma was between 18% and 36%, with a standard deviation of 9% whatever the tube (except for the single phase generator) and the applied voltage. One of the codes gives a good output and beam quality for X-ray units equipped with 100% ripple voltage generators. The use of computational codes as described in this paper provides a means of modelling relative diagnostic X-ray spectra, the usefulness of the tube output data depending on the accuracy required by the end user.




This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
F. O. Ogundare, I. O. Olarinoye, and R. I. Obed
ESTIMATION OF PATIENTS' ORGAN DOSES AND CONCEPTUS DOSES FROM SELECTED X-RAY EXAMINATIONS IN TWO NIGERIA X-RAY CENTRES
Radiat Prot Dosimetry, January 6, 2009; (2009) ncn317v1.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2004 by the British Institute of Radiology.