BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2004) 77, 52-56
© 2004 British Institute of Radiology
doi: 10.1259/bjr/62332261

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsalafoutas, I A
Right arrow Articles by Triantopoulou, C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsalafoutas, I A
Right arrow Articles by Triantopoulou, C

Short communication

Quality control of a laser camera with the SMPTE test pattern: optical density variations with printing format and frame position

I A Tsalafoutas, MSc, PhD 1 V Tsapaki, MSc, PhD 1 E Koulentianos, MD 2 and C H Triantopoulou, MD 3

1 Medical Physics Unit, 2 Radiology Department and 3 Computed Tomography Department, ‘Konstantopoulio-Agia Olga’ Hospital, 3–5 Agias Olgas, Nea Ionia, 142 33, Athens, Greece

The purpose of this study was to investigate the use of the Society of Motion Picture and Television Engineers (SMPTE) test pattern in the quality control of a modern laser camera and the variations in the optical density (OD) of the film when different formats are used. The SMPTE pattern was printed on all the available frames in eight different formats. Furthermore, six films were produced using the same format to check for any reproducibility problems. The OD values of the 11 step greyscale of the SMPTE patterns were measured with a densitometer, as well as the OD of steps 10 and 11 of the 16 step monitor greyscale printed to the left of each frame along with the SMPTE pattern. Variations up to 0.2 were observed in the OD of the same step when different formats and different frames within the same film were compared. Furthermore, the OD variations with frame position were found to follow a specific pattern. The OD variations observed with printing format and frame position can not be explained with certainty. They may indicate a laser camera malfunction and, if this is the case, limits to the maximum variation allowed should be set.




This article has been cited by other articles:


Home page
radtechHome page
K. A. KHALIFAH, A. BRINDHABAN, G. A. BALOUL, F. A. BATHER, and M. ABDULGAFOOR
Optical Density Changes In Dry-processed Films
Radiol. Technol., September 1, 2007; 79(1): 9 - 16.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
I A Tsalafoutas, G V Papoutsis, P N Maniatis, and K A Gogos
Optical density variations in CT films and their effect on image quality
Br. J. Radiol., May 1, 2006; 79(941): 425 - 431.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2004 by the British Institute of Radiology.