BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2004) 77, 28-38
© 2004 British Institute of Radiology
doi: 10.1259/bjr/93969091

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McVey, G
Right arrow Articles by Weatherburn, H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McVey, G
Right arrow Articles by Weatherburn, H

Full Paper

A study of scatter in diagnostic X-ray rooms

G McVey, DPhil and H Weatherburn, PhD

Medical Physics Department, The Churchill, Oxford Radcliffe Hospital NHS Trust, Headington, Oxford OX3 7LJ, UK

An important part of determining the radiation protection requirements during X-ray room design is the calculation of the amount of scatter inside and outside the planned locations of the shielding barriers. In this work, a Monte Carlo code has been developed to calculate the percentage scatter so that the current data can be consolidated and new data can be provided as required. Calculations have been compared with measurements to show that they are representative of scatter found in X-ray rooms. Scatter from the dose–area product meter and the collimator system were found to provide large contributions to the measured scatter. A fluoroscopy room containing a C-arm X-ray set was modelled with the Monte Carlo code. The scatter dose was calculated at an X-ray room entrance behind the protective screen, acting as a secondary barrier, at the radiographer's console. The variation of scatter with the position of the protective screen was studied. An empirical calculation, which provided reasonable agreement with the Monte Carlo calculations, was found by using new data for the variation of scatter from concrete with field size. If a door was placed in the X-ray room entrance behind the protective screen, the results showed that it would not need to be lead lined.




This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
G McVey
The effect of phantom type, beam quality, field size and field position on X-ray scattering simulated using Monte Carlo techniques
Br. J. Radiol., February 1, 2006; 79(938): 130 - 141.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2004 by the British Institute of Radiology.