BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2004) 77, 21-27
© 2004 British Institute of Radiology
doi: 10.1259/bjr/34203805

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Taylor, P M
Right arrow Articles by Johnston, K
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Taylor, P M
Right arrow Articles by Johnston, K

Full Paper

An evaluation of the impact of computer-based prompts on screen readers' interpretation of mammograms

P M Taylor, PhD1, J Champness, MSc1, R M Given-Wilson, FRCR2, H W W Potts, PhD3 and K Johnston, PhD4

1 Centre for Health Informatics and Multiprofessional Education, University College London, Archway Campus, Highgate Hill, London2 Duchess of Kent Screening Unit, Blackshaw Road, London, 3 School of Public Policy, University College London, 29/30 Tavistock Square, London and 4 Health Economics Research Centre, Institute of Health Sciences, University of Oxford, Oxford, UK

The NHS Breast Screening Programme is changing working practices in response to increased workload and manpower shortages. Radiographers are being trained as film readers. Computer aids are being considered. We have evaluated the impact of prompts placed by the R2 ImageChecker 1000 on the sensitivity and specificity of film readers, including non-radiologist film readers. 30 radiologists, 5 breast clinicians and 15 radiographers each read 180 films, including 60 cancers (20 false negative interval cases and 40 screen detected cancers). Each reader read each case twice, once with and once without computer prompts. The order in which the reading sessions were carried out was randomized separately for each reader. 36 out of 40 screen-detected cases were prompted by the ImageChecker, a sensitivity of 90%. Eight out of 20 interval cases were prompted, a sensitivity of 40%. No significant difference was found for readers' sensitivity or specificity between the prompted and unprompted conditions. No significant difference was found between the sensitivity and specificity of the different groups of film reader. No difference in impact of prompts was found for well or poorly performing film readers. The result suggests that this version of the ImageChecker would not have a significant impact on the UK screening programme.




This article has been cited by other articles:


Home page
RadiologyHome page
L. A. L. Khoo, P. Taylor, and R. M. Given-Wilson
Computer-aided Detection in the United Kingdom National Breast Screening Programme: Prospective Study
Radiology, November 1, 2005; 237(2): 444 - 449.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S M Astley
Evaluation of computer-aided detection (CAD) prompting techniques for mammography
Br. J. Radiol., January 1, 2005; 78(suppl_1): S20 - S25.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
P Taylor and R M Given-Wilson
Evaluation of computer-aided detection (CAD) devices
Br. J. Radiol., January 1, 2005; 78(suppl_1): S26 - S30.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E Alberdi, A A Povyakalo, L Strigini, P Ayton, M Hartswood, R Procter, and R Slack
Use of computer-aided detection (CAD) tools in screening mammography: a multidisciplinary investigation
Br. J. Radiol., January 1, 2005; 78(suppl_1): S31 - S40.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S M Astley
Computer-based detection and prompting of mammographic abnormalities
Br. J. Radiol., December 1, 2004; 77(suppl_2): S194 - S200.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2004 by the British Institute of Radiology.