| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Full Paper |
1 Medical Physics Directorate, University Hospital of North Staffordshire NHS Trust, Princes Road, Hartshill, Stoke on Trent ST4 7LN and 2 X-ray Department, Queens Hospital, Belvedere Road, Burton-on-Trent ST16 3SA, UK
The variation in exposure factors and patient dose, between seven centres using identical multislice CT scanners, was investigated for six standard examinations. Dose values were compared with each other and the relevant diagnostic reference level (DRL) for each examination. The range in weighted CT dose index (CTDIw) values between the seven centres was small for abdominal scans and head scans. For other scans however, such as functional endoscopic sinonasal surgery (FESS) the variations in CTDIw were as high as a factor of seven between the lowest and the highest values. At one centre a program of dose optimization had been undertaken and this centre had CTDIw values ranging from 3% to 64% lower than the average value for the seven centres. This demonstrates that significant dose reduction can be achieved through close collaboration between medical physicists, radiologists and radiographers.
This article has been cited by other articles:
![]() |
T. A. Jaffe, T. T. Yoshizumi, G. Toncheva, C. Anderson-Evans, C. Lowry, C. M. Miller, R. C. Nelson, and C. E. Ravin Radiation Dose for Body CT Protocols: Variability of Scanners at One Institution Am. J. Roentgenol., October 1, 2009; 193(4): 1141 - 1147. [Abstract] [Full Text] [PDF] |
||||
![]() |
C.B. Nauer, A. Eichenberger, P. Dubach, J. Gralla, and M. Caversaccio CT Radiation Dose for Computer-Assisted Endoscopic Sinus Surgery: Dose Survey and Determination of Dose-Reduction Limits AJNR Am. J. Neuroradiol., March 1, 2009; 30(3): 617 - 622. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Kubo, P.-J. P. Lin, W. Stiller, M. Takahashi, H.-U. Kauczor, Y. Ohno, and H. Hatabu Radiation Dose Reduction in Chest CT: A Review Am. J. Roentgenol., February 1, 2008; 190(2): 335 - 343. [Abstract] [Full Text] [PDF] |
||||
![]() |
A J Van Der Molen, W J H Veldkamp, and J Geleijns 16-slice CT: achievable effective doses of common protocols in comparison with recent CT dose surveys Br. J. Radiol., April 1, 2007; 80(952): 248 - 255. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Tsapaki, J. E. Aldrich, R. Sharma, M. A. Staniszewska, A. Krisanachinda, M. Rehani, A. Hufton, C. Triantopoulou, P. N. Maniatis, J. Papailiou, et al. Dose Reduction in CT while Maintaining Diagnostic Confidence: Diagnostic Reference Levels at Routine Head, Chest, and Abdominal CT--IAEA-coordinated Research Project Radiology, September 1, 2006; 240(3): 828 - 834. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |