BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2003) 76, 798-802
© 2003 British Institute of Radiology
doi: 10.1259/bjr/33117342

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Koller, C J
Right arrow Articles by Bettridge, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Koller, C J
Right arrow Articles by Bettridge, A

Full Paper

Variations in radiation dose between the same model of multislice CT scanner at different hospitals

C J Koller, MSc 1 J P Eatough, PhD 1 and A Bettridge, DCR(R) 2

1 Medical Physics Directorate, University Hospital of North Staffordshire NHS Trust, Princes Road, Hartshill, Stoke on Trent ST4 7LN and 2 X-ray Department, Queens Hospital, Belvedere Road, Burton-on-Trent ST16 3SA, UK

The variation in exposure factors and patient dose, between seven centres using identical multislice CT scanners, was investigated for six standard examinations. Dose values were compared with each other and the relevant diagnostic reference level (DRL) for each examination. The range in weighted CT dose index (CTDIw) values between the seven centres was small for abdominal scans and head scans. For other scans however, such as functional endoscopic sinonasal surgery (FESS) the variations in CTDIw were as high as a factor of seven between the lowest and the highest values. At one centre a program of dose optimization had been undertaken and this centre had CTDIw values ranging from 3% to 64% lower than the average value for the seven centres. This demonstrates that significant dose reduction can be achieved through close collaboration between medical physicists, radiologists and radiographers.




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
T. A. Jaffe, T. T. Yoshizumi, G. Toncheva, C. Anderson-Evans, C. Lowry, C. M. Miller, R. C. Nelson, and C. E. Ravin
Radiation Dose for Body CT Protocols: Variability of Scanners at One Institution
Am. J. Roentgenol., October 1, 2009; 193(4): 1141 - 1147.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
C.B. Nauer, A. Eichenberger, P. Dubach, J. Gralla, and M. Caversaccio
CT Radiation Dose for Computer-Assisted Endoscopic Sinus Surgery: Dose Survey and Determination of Dose-Reduction Limits
AJNR Am. J. Neuroradiol., March 1, 2009; 30(3): 617 - 622.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. Kubo, P.-J. P. Lin, W. Stiller, M. Takahashi, H.-U. Kauczor, Y. Ohno, and H. Hatabu
Radiation Dose Reduction in Chest CT: A Review
Am. J. Roentgenol., February 1, 2008; 190(2): 335 - 343.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
A J Van Der Molen, W J H Veldkamp, and J Geleijns
16-slice CT: achievable effective doses of common protocols in comparison with recent CT dose surveys
Br. J. Radiol., April 1, 2007; 80(952): 248 - 255.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. Tsapaki, J. E. Aldrich, R. Sharma, M. A. Staniszewska, A. Krisanachinda, M. Rehani, A. Hufton, C. Triantopoulou, P. N. Maniatis, J. Papailiou, et al.
Dose Reduction in CT while Maintaining Diagnostic Confidence: Diagnostic Reference Levels at Routine Head, Chest, and Abdominal CT--IAEA-coordinated Research Project
Radiology, September 1, 2006; 240(3): 828 - 834.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2003 by the British Institute of Radiology.