Short communication |
Department of Medical Physics & Engineering, Leeds Teaching Hospitals NHS Trust, St James's University Hospital, Leeds LS9 7TF, UK
The use of non-permanent, digital image display, i.e. soft-copy display, is increasing within hospitals due to the growth in the use of digital modalities and picture archiving and communication systems (PACS). Non-dedicated image review using standard PCs is being employed as a cost-effective method of image access. These workstations do not have specialized display systems and are likely to suffer from inconsistent image presentation. The Digital Imaging and Communications in Medicine (DICOM) Working Group 11 has developed a display function standard (part 14) to standardize the display of grey scale images. Although this standard is starting to be adopted by manufacturers of proprietary reporting systems it is not easily applied to the existing number of non-dedicated, PC-based review systems. The aim of this work was to investigate whether display consistency could be achieved simply and reproducibly on these systems, outside of the DICOM standard: part 14, by adjusting monitor brightness and contrast settings and using the Society of Motion Picture and Television Engineers (SMPTE) digital test pattern. The study showed that by adjusting the brightness and contrast settings alone it was possible to approximate the display characteristic curves to the grey scale standard display function (GSDF) defined in the DICOM standard: part 14, but only at unacceptably low luminances. Intradisplay and interdisplay consistency could be achieved using a simple monitor set-up procedure and the SMPTE test pattern.
This article has been cited by other articles:
![]() |
D S Brettle Display considerations for hospital-wide viewing of soft copy images Br. J. Radiol., July 1, 2007; 80(955): 503 - 507. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. J. Robson and C. J. Kotre Pilot study into optimisation of viewing conditions for electronically displayed images Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 298 - 303. [Abstract] [Full Text] [PDF] |
||||
![]() |
D S Brettle and S E Bacon A method for verified access when using soft copy display Br. J. Radiol., August 1, 2005; 78(932): 749 - 751. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Berkhout, D. Beuger, G. Sanderink, and P. van der Stelt The dynamic range of digital radiographic systems: dose reduction or risk of overexposure? Dentomaxillofac. Radiol., January 1, 2004; 33(1): 1 - 5. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| BJR | DMFR | IMAGING | ALL BIR JOURNALS |