British Journal of Radiology (2003) 76, 638-647
© 2003 British Institute of Radiology
doi: 10.1259/bjr/21647806

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schultz, F W
Right arrow Articles by Zoetelief, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schultz, F W
Right arrow Articles by Zoetelief, J

Full Paper

Monte Carlo calculations for assessment of radiation dose to patients with congenital heart defects and to staff during cardiac catheterizations

F W Schultz, PhD 1 J Geleijns, PhD 2 F M Spoelstra, PhD 2 and J Zoetelief, PhD 1

1 Interfaculty Reactor Institute, Delft University of Technology, Mekelweg 15, 2629 JB Delft and 2 Department of Radiology, Leiden University Medical Center, PO Box 9600, 2300 RC Leiden, The Netherlands

Correspondence: F W Schultz, Interfaculty Reactor Institute (IRI/ST-MSF), Mekelweg 15, 2629 JB Delft, The Netherlands

Effective dose is an important quantity in relation to assessment of radiation risk. Organ and effective doses to paediatric patients undergoing diagnostic and therapeutic heart catheterization procedures can be assessed by combining relatively simple measurements, e.g. of dose–area product (DAP), and calculated dose conversion factors (DCF). This also holds for the radiation dose to the hospital staff, e.g. the cardiologist. Monte Carlo (MC) simulation of radiation transport in mathematical anthropomorphic phantoms is used to obtain the DCFs, which strongly depend on beam quality and geometrical parameters. The performance of a dedicated fast MC code (PCXMC) for patient dosimetry is compared with that of a more elaborate general purpose MC code (MCNP). Resulting organ doses sometimes may differ considerably, partly due to phantom differences. While MCNP uses separate male and female mathematical phantoms, PCXMC uses a hermaphrodite. However, both codes yield effective doses that agree rather well, so PCXMC can be used for convenience. The MCNP code is used to calculate the effective dose to the cardiologist exposed to radiation scattered from the patient. Without protective clothing, effective dose per procedure to the cardiologist is at least two orders of magnitude lower than that to the patient. The effectiveness of various types and thickness of protective clothing has been evaluated for one view of one cardiac catheterization. The results of the calculations do not contradict experimental studies from the literature. MC simulation may serve as a useful tool to improve the accuracy of estimating occupational effective dose from personal dose monitors.




This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
A KARAMBATSAKIDOU, B SAHLGREN, B HANSSON, M LIDEGRAN, and A FRANSSON
Effective dose conversion factors in paediatric interventional cardiology
Br. J. Radiol., September 1, 2009; 82(981): 748 - 755.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
V. Tsapaki, S. Kottou, S. Korniotis, N. Nikolaki, S. Rammos, and S. C. Apostolopoulou
RADIATION DOSES IN PAEDIATRIC INTERVENTIONAL CARDIOLOGY PROCEDURES
Radiat Prot Dosimetry, January 2, 2009; (2009) ncn313v1.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
C.B. Nauer, F. Kellner-Weldon, G. Von Allmen, D. Schaller, and J. Gralla
Effective Doses from Scan Projection Radiographs of the Head: Impact of Different Scanning Practices and Comparison with Conventional Radiography
AJNR Am. J. Neuroradiol., January 1, 2009; 30(1): 155 - 159.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
B. J. Irving, G. J. Maree, E. R. Hering, and T. S. Douglas
Radiation dose from a linear slit scanning X-ray machine with full-body imaging capabilities
Radiat Prot Dosimetry, July 1, 2008; 130(4): 482 - 489.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
F. W. Schultz and J. Zoetelief
DOSEMETER READINGS AND EFFECTIVE DOSE TO THE CARDIOLOGIST WITH PROTECTIVE CLOTHING IN A SIMULATED INTERVENTIONAL PROCEDURE
Radiat Prot Dosimetry, April 3, 2008; (2008) ncn085v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. Smans, E. Vano, R. Sanchez, F. W. Schultz, J. Zoetelief, T. Kiljunen, C. Maccia, H. Jarvinen, R. Bly, A. Kosunen, et al.
Results of a European survey on patient doses in paediatric radiology
Radiat Prot Dosimetry, March 1, 2008; 129(1-3): 204 - 210.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
S. H. Park, J. K. Lee, and C. Lee
Dose conversion coefficients calculated using tomographic phantom, KTMAN-2, for X-ray examination of cardiac catheterisation
Radiat Prot Dosimetry, February 1, 2008; 128(3): 351 - 358.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
T Siiskonen, M Tapiovaara, A Kosunen, M Lehtinen, and E Vartiainen
Monte Carlo simulations of occupational radiation doses in interventional radiology
Br. J. Radiol., June 1, 2007; 80(954): 460 - 468.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
R R Bridcut, E Murphy, A Workman, P Flynn, and R J Winder
Patient dose from 3D rotational neurovascular studies
Br. J. Radiol., May 1, 2007; 80(953): 362 - 366.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
D G W Onnasch, F K Schroder, G Fischer, and H-H Kramer
Diagnostic reference levels and effective dose in paediatric cardiac catheterization
Br. J. Radiol., March 1, 2007; 80(951): 177 - 185.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. Th. M. Jansen and J. Zoetelief
Dose constraints and guidance for exposure of individuals knowingly and willingly helping in the support and comfort of individuals undergoing medical exposure
Radiat Prot Dosimetry, June 1, 2006; 118(3): 315 - 324.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
F. W. Schultz and J. Zoetelief
Estimating effective dose for a cardiac catheterisation procedure with single or double personal dosemeters
Radiat Prot Dosimetry, May 1, 2006; 118(2): 196 - 204.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
F. W. Schultz and J. Zoetelief
Dose conversion coefficients for interventional procedures
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 225 - 230.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. N. Kroon
3-Dimensional rotational X-ray imaging, 3D-RX: image quality and patient dose simulation for optimisation studies
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 341 - 349.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2003 by the British Institute of Radiology.