BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2003) 76, 625-630
© 2003 British Institute of Radiology
doi: 10.1259/bjr/20434900

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kemerink, G J
Right arrow Articles by van Engelshoven, J M A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kemerink, G J
Right arrow Articles by van Engelshoven, J M A

Full Paper

The effect of equipment set up on patient radiation dose in conventional and CT angiography of the renal arteries

G J Kemerink, PhD1, M W de Haan, MD1, G B C Vasbinder, MD1, M J Frantzen1, F W Schultz, PhD2, J Zoetelief, PhD2, J Th M Jansen, PhD2 and J M A van Engelshoven, MD, PhD1

1 Department of Radiology, University Hospital Maastricht, P. Debijelaan 25, 6229 HX Maastricht and 2 Interfaculty Reactor Institute, Delft University of Technology, Mekelweg 15, 2629 JB Delft, The Netherlands

Patient radiation dose in angiography of the renal arteries was assessed and optimized after installing new radiological equipment. In three separate studies (n=50, 25 and 20) patient exposure was monitored in detail. For the first study default factory settings were used, for the second the number of digital subtraction angiography (DSA) images was halved and the X-ray beam filtering during fluoroscopy was increased, and for the third study filtering during DSA was increased as well. Standard projections were derived and used in Monte Carlo simulations to derive dose conversion coefficients to calculate effective dose from the dose–area product (DAP). Dose conversion coefficients were also calculated for CT angiography (CTA). Using default factory settings on the new angiography system, DAP, number of images and effective dose were much higher than on the replaced unit. For the studies given above, DAP was reduced from 144 Gy cm2 to 65 Gy cm2 to 32 Gy cm2, and effective dose from 22 mSv to 11 mSv to 9.1 mSv, respectively. Effective dose due to CTA was 5.2 mSv. It is concluded that modern angiography systems, resulting in high customer satisfaction, may readily cause much higher patient exposure than older systems. These doses may also be much higher than necessary. Optimization before putting such systems into use is absolutely essential. Internationally accepted recommendations for image quality and technique factors in angiography would be of great help.




This article has been cited by other articles:


Home page
RadiologyHome page
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Radiology, July 1, 2008; 248(1): 254 - 263.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
W.H. Backes and R.J. Nijenhuis
Advances in Spinal Cord MR Angiography
AJNR Am. J. Neuroradiol., April 1, 2008; 29(4): 619 - 631.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
F. W. Schultz and J. Zoetelief
Dose conversion coefficients for interventional procedures
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 225 - 230.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2003 by the British Institute of Radiology.