British Journal of Radiology (2003) 76, 464-472
© 2003 British Institute of Radiology
doi: 10.1259/bjr/82965103

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gallacher, D J
Right arrow Articles by Saunders, J E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gallacher, D J
Right arrow Articles by Saunders, J E

Full Paper

Use of a quality index in threshold contrast detail detection measurements in television fluoroscopy

D J Gallacher, MPhil1, A Mackenzie, MSc2, S Batchelor, MSc1, J Lynch, MSc3 and J E Saunders, BSc4

1 Medical Physics Department, Guy's and St Thomas' Hospital, London SE1 7EH, 2 King's Centre for Assessment of Radiological Equipment (KCARE), King's Hospital, London, 3 Medical Physics Department, Princess Margaret Hospital, Swindon and 4 Formerly Medical Physics Department, Guy's and St Thomas' Hospital Trust, London SE1 7EH, UK

The use of a single index to assist in quality control procedures of X-ray television fluoroscopy systems was investigated. A single quality index was devised incorporating a measure of threshold contrast detail detectability (TCDD) performance and taking into account image intensifier input kerma rate, field size, differences in radiation beam quality, and pulsed fluoroscopy. This was applied to a number of clinical systems to investigate changes in image quality index quantified over time. Accepted measurement protocols were used to obtain these measurements. The results show system performance for different systems and can establish the decline in performance parameters over time or assess non-optimal image quality with clinical systems in field measurements. The systems studied were assessed with a variety of performance parameters including TCDD results, low contrast sensitivity, limiting resolution, and image intensifier input kerma rate under clinical modes of operation. The TCDD quality index, and dose normalized quality index, were found to be useful image quality assessment parameters for serial testing of systems, which augment the use of graphical methods for the display of TCDD curves.




This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
C. Walsh, D. Gorman, P. Byrne, A. Larkin, A. Dowling, and J. F. Malone
QUALITY ASSURANCE OF COMPUTED AND DIGITAL RADIOGRAPHY SYSTEMS
Radiat Prot Dosimetry, March 4, 2008; (2008) ncn047v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. Kepler and A. Vladimirov
Optimisation strategies introduced for CR at health care centres in Estonia
Radiat Prot Dosimetry, March 1, 2008; 129(1-3): 127 - 131.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
I D Honey, A Mackenzie, and D S Evans
Investigation of optimum energies for chest imaging using film-screen and computed radiography
Br. J. Radiol., May 1, 2005; 78(929): 422 - 427.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
D S Evans, A Mackenzie, C P Lawinski, and D Smith
Threshold contrast detail detectability curves for fluoroscopy and digital acquisition using modern image intensifier systems
Br. J. Radiol., September 1, 2004; 77(921): 751 - 758.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 