BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (2003) 76, 398-405
© 2003 British Institute of Radiology
doi: 10.1259/bjr/76222078

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by van Soldt, R T M
Right arrow Articles by Zoetelief, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by van Soldt, R T M
Right arrow Articles by Zoetelief, J

Full Paper

Survey of posteroanterior chest radiography in The Netherlands: patient dose and image quality

R T M van Soldt 1 D Zweers 2 L van den Berg 1 J Geleijns 2 J Th M Jansen 1 and J Zoetelief 1

1 Interfaculty Reactor Institute Delft University of Technology, Mekelweg 15, 2629 JB Delft and 2 Department of Radiology, Leiden University Medical Centre, Albinusdreef 2, 2333 ZA Leiden, The Netherlands

Correspondence: J Zoetelief

Council Directive 97/43/Euratom (Medical Exposure Directive) states that member States of the European Union shall promote the establishment and use of diagnostic reference levels for radio-diagnostic examinations. Dose surveys can form the basis for the establishment of diagnostic reference levels. In view of the implementation of the Medical Exposure Directive in the Netherlands, a survey of dose and image quality has been performed for posteroanterior (PA) chest radiography in 2001. In this survey, 25 participants were selected from a list of 175 Dutch hospitals, whereas in a previous PA chest survey (about 10 years ago) participation was voluntary and participants came predominantly from the south-western part of the Netherlands. For conventional screen–film PA chest radiography, the present results for patient dose and image quality are quite similar to those results from the previous survey. The fraction of conventional X-ray systems utilizing lung compensation filters has remained approximately the same. For dedicated digital chest radiography systems, image quality is better than for conventional systems, but doses vary and can assume relatively high values. The results indicate that there are still possibilities for dose reduction, without loss of image quality. The 75 percentile value of the entrance surface dose distribution is approximately 0.13 mGy.




This article has been cited by other articles:


Home page
RadiologyHome page
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Radiology, July 1, 2008; 248(1): 254 - 263.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. Zoetelief, H. H. E. Idris, and J. T. M. Jansen
Investigation of possible methods for equipment self-tests in digital radiology
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 269 - 273.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. Zoetelief, R. T. M. van Soldt, I. I. Suliman, J. T. M. Jansen, and H. Bosmans
Quality control of equipment used in digital and interventional radiology
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 277 - 282.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
V. Neofotistou, V. Tsapaki, S. Kottou, A. Schreiner-Karoussou, and E. Vano
Does digital imaging decrease patient dose? A pilot study and review of the literature
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 204 - 210.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
I D Honey, A Mackenzie, and D S Evans
Investigation of optimum energies for chest imaging using film-screen and computed radiography
Br. J. Radiol., May 1, 2005; 78(929): 422 - 427.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
G. Compagnone, L. Pagan, and C. Bergamini
Local diagnostic reference levels in standard X-ray examinations
Radiat Prot Dosimetry, April 18, 2005; 113(1): 54 - 63.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2003 by the British Institute of Radiology.