Department of Radiology, University Hospitals of Leicester NHS Trust, Leicester General Hospital, Gwendolen Road, Leicester LE5 4PW, UK
We report the use of a covered stent to successfully treat a pseudoaneurysm of the popliteal artery, which occurred following total knee arthroplasty. Percutaneous endovascular repair offers a safe alternative to surgical management of this condition.