British Journal of Radiology (2003) 76, 129-131
© 2003 British Institute of Radiology
doi: 10.1259/bjr/58851704

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Isoardi, P
Right arrow Articles by Ropolo, R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Isoardi, P
Right arrow Articles by Ropolo, R

Short communication

Measurement of dose–width product in panoramic dental radiology

P Isoardi, PhD and R Ropolo, PhD

Department of Health Physics, Azienda Ospedaliera San Giovanni Battista di Torino, c.so Bramante 88, 10126 Torino, Italy

The National Radiological Protection Board has recommended the introduction of dose–width product (DWP) for the measurement of patient dose in panoramic dental radiology. The present work describes a method for measuring DWP using a pencil ionization chamber. The technique was tested on five panoramic dental units; the reproducibility of the method was 5.7%. In order to test the method, DWP was also assessed using thermoluminescent dosemeters and film. The results obtained agreed within 8.6% with those obtained using the pencil ionization chamber method. The proposed method appears to be simple and precise.




This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
C. J. Martin
RADIATION DOSIMETRY FOR DIAGNOSTIC MEDICAL EXPOSURES
Radiat Prot Dosimetry, March 28, 2008; (2008) ncm495v1.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
S Lofthag-Hansen, A Thilander-Klang, A Ekestubbe, E Helmrot, and K Grondahl
Calculating effective dose on a cone beam computed tomography device: 3D Accuitomo and 3D Accuitomo FPD
Dentomaxillofac. Radiol., February 1, 2008; 37(2): 72 - 79.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
P Doyle, C J Martin, and J Robertson
Techniques for measurement of dose width product in panoramic dental radiography
Br. J. Radiol., February 1, 2006; 79(938): 142 - 147.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
E. Helmrot and G. Alm Carlsson
Measurement of radiation dose in dental radiology
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 168 - 171.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2003 by the British Institute of Radiology.