British Journal of Radiology 75 (2002),819-830 © 2002 The British Institute of Radiology

Full paper

Influence of patient age on normalized effective doses calculated for CT examinations

A Khursheed, PhD M C Hillier P C Shrimpton, PhD and B F Wall, BSc

National Radiological Protection Board, Chilton, Didcot, Oxfordshire OX11 0RQ, UK

Monte Carlo simulations of CT examinations have been performed to estimate effective doses, normalized to axial air kerma, for six mathematical phantoms representing ages from newborn to adult, and for three CT scanner models covering a range of designs. Organ doses were calculated for CT exposures of contiguous, 1 cm wide, transverse slices in each phantom and summed to give normalized effective doses for scans of four regions of the trunk and head. In all cases an inverse trend is observed between normalized effective dose and phantom age, with the dose to the newborn from head and neck scans being 2.2–2.5 times higher than that to the adult, depending on scanner model. Corresponding increases for scans of the trunk region are more variable between scanners and range from a factor of 1.3 to 2.4. If typical clinical exposure conditions for adults are also utilized for children, then, for example, the effective dose to the newborn from a chest scan could be above 15 mSv. It is concluded that CT has the potential to deliver significantly greater radiation doses to children than to adults and in view of their greater susceptibility to radiation effects, special efforts should be made in clinical practice to reduce doses to children by the use of size-specific scan protocols.




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
M. d. Bastos, E. Y. Lee, K. J. Strauss, D. Zurakowski, D. A. Tracy, and P. M. Boiselle
Motion Artifact on High-Resolution CT Images of Pediatric Patients: Comparison of Volumetric and Axial CT Methods
Am. J. Roentgenol., November 1, 2009; 193(5): 1414 - 1418.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. M. Alessio, P. E. Kinahan, V. Manchanda, V. Ghioni, L. Aldape, and M. T. Parisi
Weight-Based, Low-Dose Pediatric Whole-Body PET/CT Protocols
J. Nucl. Med., October 1, 2009; 50(10): 1570 - 1578.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Loeve, M. H. Lequin, M. de Bruijne, I. J. C. Hartmann, K. Gerbrands, M. van Straten, W. C. J. Hop, and H. A. W. M. Tiddens
Cystic Fibrosis: Are Volumetric Ultra-Low-Dose Expiratory CT Scans Sufficient for Monitoring Related Lung Disease?
Radiology, October 1, 2009; 253(1): 223 - 229.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. D. Deak, O. Langner, M. Lell, and W. A. Kalender
Effects of Adaptive Section Collimation on Patient Radiation Dose in Multisection Spiral CT
Radiology, July 1, 2009; 252(1): 140 - 147.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. C. Shrimpton, B. F. Wall, T. T. Yoshizumi, L. M. Hurwitz, and P. C. Goodman
Effective Dose and Dose-Length Product in CT
Radiology, February 1, 2009; 250(2): 604 - 605.
[Full Text] [PDF]


Home page
RadiologyHome page
M. J. Wan, M. Krahn, W. J. Ungar, E. Caku, L. Sung, L. S. Medina, and A. S. Doria
Acute Appendicitis in Young Children: Cost-effectiveness of US versus CT in Diagnosis--A Markov Decision Analytic Model
Radiology, February 1, 2009; 250(2): 378 - 386.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. Gu, B. Bednarz, X. G. Xu, and S. B. Jiang
Assessment of patient organ doses and effective doses using the VIP-Man adult male phantom for selected cone-beam CT imaging procedures during image guided radiation therapy
Radiat Prot Dosimetry, September 1, 2008; 131(4): 431 - 443.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
C. H. Lee, J. M. Goo, H. J. Ye, S.-J. Ye, C. M. Park, E. J. Chun, and J.-G. Im
Radiation Dose Modulation Techniques in the Multidetector CT Era: From Basics to Practice1
RadioGraphics, September 1, 2008; 28(5): 1451 - 1459.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Radiology, July 1, 2008; 248(1): 254 - 263.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
W. Huda and A. Vance
Patient Radiation Doses from Adult and Pediatric CT
Am. J. Roentgenol., February 1, 2007; 188(2): 540 - 546.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
P C Shrimpton, M C Hillier, M A Lewis, and M Dunn
National survey of doses from CT in the UK: 2003
Br. J. Radiol., December 1, 2006; 79(948): 968 - 980.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
P. A. de Jong, J. R. Mayo, K. Golmohammadi, Y. Nakano, M. H. Lequin, H. A. W. M. Tiddens, J. Aldrich, H. O. Coxson, and D. D. Sin
Estimation of Cancer Mortality Associated with Repetitive Computed Tomography Scanning
Am. J. Respir. Crit. Care Med., January 15, 2006; 173(2): 199 - 203.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. S. Brody, H. A. W. M. Tiddens, R. G. Castile, H. O. Coxson, P. A. de Jong, J. Goldin, W. Huda, F. R. Long, M. McNitt-Gray, M. Rock, et al.
Computed Tomography in the Evaluation of Cystic Fibrosis Lung Disease
Am. J. Respir. Crit. Care Med., November 15, 2005; 172(10): 1246 - 1252.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
I. A. Castellano, D. R. Dance, and P. M. Evans
CT dosimetry: getting the best from the adult Cristy phantom
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 321 - 325.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. D. Nawfel, P. F. Judy, A. R. Schleipman, and S. G. Silverman
Patient Radiation Dose at CT Urography and Conventional Urography
Radiology, July 1, 2004; 232(1): 126 - 132.