BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Power, N P
Right arrow Articles by Reznek, R H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Power, N P
Right arrow Articles by Reznek, R H
British Journal of Radiology 75 (2002),401-408 © 2002 The British Institute of Radiology

Full Paper

Optimization of scanning parameters for CT colonography

N P Power, MRCPI, FRCR 1 M D Pryor, MSc 2 A Martin, DCR, PgDip 1 J Horrocks, MSc, PhD 2 A M McLean, FRCP, FRCR 1 and R H Reznek, FRCP, FRCR 1

Departments of 1 Radiology and 2 Clinical Physics, St. Bartholomew's Hospital, West Smithfield, London EC1A 7EB, UK

To determine the optimal collimation, pitch and reconstruction interval for CT colonography, 10 spherical polyps between 1 mm and 10 mm diameter and made of tissue equivalent material with a CT number of 40 Hounsfield units (HU) were placed in the colon of an anthropomorphic phantom. The phantom was scanned at slice thicknesses of 3 mm, 5 mm and 7 mm and pitches of 1.0, 1.3, 1.5, 1.7 and 2.0 on an IGE Hispeed advantage system. Images were reconstructed for each scanning parameter at the minimum intervals allowed along the z-axis. The optimum scanning protocol was assessed by measuring maximum contrast between the polyp and air, sensitivity for detection of each polyp along the z-axis, and relative radiation dose. In addition, images were reviewed separately by two radiologists who graded polyp conspicuity as: 0, not seen; 1, faintly seen; 2, well seen. It was found that varying the scanning parameters caused a marked alteration in the maximum contrast between each polyp and air. For example, for the 5 mm polyp, the range of contrasts from best to worst case was 910–490 HU. It was noted that with contrasts of less than 500 HU, polyps were only faintly seen. A slice thickness of 3 mm with a pitch of 2 offers optimal polyp conspicuity with a relatively low radiation dose, we conclude that scanning parameters can be optimized for threshold contrast, radiation dose and subjective conspicuity. We propose an optimal parameter of 3 mm slice thickness and pitch 2.




This article has been cited by other articles:


Home page
RadiologyHome page
S. H. Kim, J. M. Lee, C.-I. Shin, H. C. Kim, J.-G. Lee, J. H. Kim, J. Y. Choi, H. W. Eun, J. K. Han, J. Y. Lee, et al.
Effects of Spatial Resolution and Tube Current on Computer-aided Detection of Polyps on CT Colonographic Images: Phantom Study
Radiology, August 1, 2008; 248(2): 492 - 503.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y. Onodera, T. Omatsu, S. Takeuchi, N. Shinagawa, K. Yamazaki, T. Nishioka, and K. Miyasaka
Enhanced Virtual Bronchoscopy Using the Pulmonary Artery: Improvement in Route Mapping for Ultraselective Transbronchial Lung Biopsy
Am. J. Roentgenol., October 1, 2004; 183(4): 1103 - 1110.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Hoppe, C. Quattropani, A. Spreng, J. Mattich, P. Netzer, and H.-P. Dinkel
Virtual Colon Dissection with CT Colonography Compared with Axial Interpretation and Conventional Colonoscopy: Preliminary Results
Am. J. Roentgenol., May 1, 2004; 182(5): 1151 - 1158.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. K. Kalra, M. M. Maher, T. L. Toth, L. M. Hamberg, M. A. Blake, J.-A. Shepard, and S. Saini
Strategies for CT Radiation Dose Optimization
Radiology, March 1, 2004; 230(3): 619 - 628.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Wessling, R. Fischbach, N. Meier, T. Allkemper, J. Klusmeier, K. Ludwig, and W. Heindel
CT Colonography: Protocol Optimization with Multi-Detector Row CT--Study in an Anthropomorphic Colon Phantom
Radiology, September 1, 2003; 228(3): 753 - 759.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2002 by the British Institute of Radiology.