The aim of this study was to develop a method of obtaining the same levels of CT image noise for patients of various sizes to minimize radiation dose. Two CT systems were evaluated regarding noise characteristics using phantoms and dosimetric measurements. Both CT systems performed well at dose levels used in normal clinical imaging, but only one was found to be suitable for low radiation dose applications. The CT system with the lowest noise level was used for further detailed studies. A simple strategy for manual selection of patient-specific scan parameters, considering patient size and required image quality, was implemented and verified on 11 volunteers. Images were obtained with at least the prescribed image quality at significantly reduced radiation dose levels compared with standard scan parameters. Depending on the diameter of the tomographic section, i.e. size of the subject, the dose levels could be reduced to 145% of the radiation dose with standard scan parameters (120 kV, 250 mAs, 10 mm). The results indicate a general potential for dose reduction in CT for slim patients. For tissue volume determination, large dose reductions can be achieved by adjusting the scan parameters for each individual. The concept of patient-specific scan parameters could be fully automated in the CT system design, but would require the scan to be specified in terms of image quality rather than X-ray tube load.
This article has been cited by other articles:
![]() |
J. M. Kindblom, M. Lorentzon, A. Hellqvist, L. Lonn, J. Brandberg, S. Nilsson, E. Norjavaara, and C. Ohlsson BMI Changes During Childhood and Adolescence as Predictors of Amount of Adult Subcutaneous and Visceral Adipose Tissue in Men: The GOOD Study Diabetes, April 1, 2009; 58(4): 867 - 874. [Abstract] [Full Text] [PDF] |
||||
![]() |
J KULLBERG, J BRANDBERG, J-E ANGELHED, H FRIMMEL, E BERGELIN, L STRID, H AHLSTROM, L JOHANSSON, and L LONN Whole-body adipose tissue analysis: comparison of MRI, CT and dual energy X-ray absorptiometry Br. J. Radiol., February 1, 2009; 82(974): 123 - 130. [Abstract] [Full Text] [PDF] |
||||
![]() |
J BRANDBERG, L LONN, E BERGELIN, L SJOSTROM, E FORSSELL-ARONSSON, and G STARCK Accurate tissue area measurements with considerably reduced radiation dose achieved by patient-specific CT scan parameters Br. J. Radiol., October 1, 2008; 81(970): 801 - 808. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Vandenput, D. Mellstrom, M. Lorentzon, C. Swanson, M. K. Karlsson, J. Brandberg, L. Lonn, E. Orwoll, U. Smith, F. Labrie, et al. Androgens and Glucuronidated Androgen Metabolites Are Associated with Metabolic Risk Factors in Men J. Clin. Endocrinol. Metab., November 1, 2007; 92(11): 4130 - 4137. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Hur, S. W. Hong, S. Y. Kim, Y. H. Kim, Y. J. Hwang, W. R. Lee, and S. J. Cha Uniform Image Quality Achieved by Tube Current Modulation Using SD of Attenuation in Coronary CT Angiography Am. J. Roentgenol., July 1, 2007; 189(1): 188 - 196. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Kindblom, M. Lorentzon, E. Norjavaara, L. Lonn, J. Brandberg, J.-E. Angelhed, A. Hellqvist, S. Nilsson, and C. Ohlsson Pubertal Timing Is an Independent Predictor of Central Adiposity in Young Adult Males: The Gothenburg Osteoporosis and Obesity Determinants Study Diabetes, November 1, 2006; 55(11): 3047 - 3052. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Franco, J. D Veldhuis, A. Iranmanesh, J. Brandberg, L. Lonn, B. Andersson, B.-A. Bengtsson, J. Svensson, and G. Johannsson Thigh intermuscular fat is inversely associated with spontaneous GH release in post-menopausal women with abdominal obesity. Eur. J. Endocrinol., August 1, 2006; 155(2): 261 - 268. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Campbell, M. K. Kalra, S. Rizzo, M. M. Maher, and J.-A. Shepard Scanning Beyond Anatomic Limits of the Thorax in Chest CT: Findings, Radiation Dose, and Automatic Tube Current Modulation Am. J. Roentgenol., December 1, 2005; 185(6): 1525 - 1530. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. K. Kalra, S. Rizzo, M. M. Maher, E. F. Halpern, T. L. Toth, J.-A. O. Shepard, and S. L. Aquino Chest CT Performed with Z-Axis Modulation: Scanning Protocol and Radiation Dose Radiology, October 1, 2005; 237(1): 303 - 308. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Menke Comparison of Different Body Size Parameters for Individual Dose Adaptation in Body CT of Adults Radiology, August 1, 2005; 236(2): 565 - 571. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Ledenius, M. Gustavsson, S. Johansson, F. Stalhammar, J. Soderberg, L. M. Wiklund, and A. Thilander Klang A method of predicting the image noise in paediatric multi-slice computed tomography images Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 313 - 316. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Irie and H. Inoue Individual Modulation of the Tube Current-Seconds to Achieve Similar Levels of Image Noise in Contrast-Enhanced Abdominal CT Am. J. Roentgenol., May 1, 2005; 184(5): 1514 - 1518. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. S. Y. Ho, W. W-m. Lam, S. C. P. Ng, M. K. Lam, M. T. V. Chan, W. S. Poon, and C. Metreweli Cerebral Vasoreactivity: A Comparison of Color Velocity Imaging Quantification and Stable Xenon-Enhanced CT Am. J. Roentgenol., March 1, 2005; 184(3): 948 - 952. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. K. Kalra, M. M. Maher, T. L. Toth, L. M. Hamberg, M. A. Blake, J.-A. Shepard, and S. Saini Strategies for CT Radiation Dose Optimization Radiology, March 1, 2004; 230(3): 619 - 628. [Abstract] [Full Text] [PDF] |
||||
![]() |
C J Koller, J P Eatough, and A Bettridge Variations in radiation dose between the same model of multislice CT scanner at different hospitals Br. J. Radiol., November 1, 2003; 76(911): 798 - 802. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. K. Kalra, C. Wittram, M. M. Maher, A. Sharma, G. B. Avinash, K. Karau, T. L. Toth, E. Halpern, S. Saini, and J.-A. Shepard Can Noise Reduction Filters Improve Low-Radiation-Dose Chest CT Images? Pilot Study Radiology, July 1, 2003; 228(1): 257 - 264. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| BJR | DMFR | IMAGING | ALL BIR JOURNALS |