BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Avilés Lucas, P
Right arrow Articles by Vañó Carruana, E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Avilés Lucas, P
Right arrow Articles by Vañó Carruana, E
British Journal of Radiology 74 (2001),1128-1136 © 2001 The British Institute of Radiology

Full paper

Analysis of surface dose variation in CT procedures

P Avilés Lucas, MSc 1 I A Castellano, MSc, MIPEM 1 D R Dance, PhD, FIPEM 1 and E Vañó Carruana, PhD 2

1Physics Department, The Royal Marsden NHS Trust, Fulham Road, London SW3 6JJ, UK and 2Departamento de Radiología, Facultad de Medicina, Universidad Complutense de Madrid, Madrid 28040, Spain

An experimental and theoretical study has been made of the variations in air kerma–length product (AKLP) at the surface of a phantom exposed in a CT scanner, using clinical parameters. For the theoretical part, a computer simulation was developed, based on a simple analytical model, requiring information generic to the scanner model. The effects of patient size, position within the gantry plane and beam-shaping filter type were studied using three different elliptical phantoms. A dose reduction technique based on a sinusoidal tube current modulation system was also investigated. The surface AKLP was shown to be independent of phantom size (within experimental error) but decreases as the surface moves vertically away from the isocentre. The major contributor to this variation is the beam-shaping filter. A maximum difference of 19% between the values of surface AKLP was calculated for the two beam-shaping filters available. When the tube current modulation system was used, the maximum surface dose reduction was 18%. A maximum difference of 2% was found between measurements and computer simulations. It is therefore possible to predict the behaviour of AKLP using the analytical model. As the dose measured on the surface of a patient is simply related to AKLP, the model can be applied to data obtained from patient surface dose surveys and can be helpful in interpreting the sources of variation in the latter.




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
I. A. Tsalafoutas, V. Tsapaki, C. Triantopoulou, C. Pouli, V. Kouridou, I. Fagadaki, and J. Papailiou
Comparison of Measured and Calculated Skin Doses in CT-Guided Interventional Procedures
Am. J. Roentgenol., November 1, 2008; 191(5): 1601 - 1607.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Li, U. K. Udayasankar, T. L. Toth, J. Seamans, W. C. Small, and M. K. Kalra
Automatic Patient Centering for MDCT: Effect on Radiation Dose
Am. J. Roentgenol., February 1, 2007; 188(2): 547 - 552.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
P. Aviles Lucas, D. R. Dance, I. A. Castellano, and E. Vano
Estimation of the peak entrance surface air kerma for patients undergoing computed tomography-guided procedures
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 317 - 320.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. K. Kalra, C. Wittram, M. M. Maher, A. Sharma, G. B. Avinash, K. Karau, T. L. Toth, E. Halpern, S. Saini, and J.-A. Shepard
Can Noise Reduction Filters Improve Low-Radiation-Dose Chest CT Images? Pilot Study
Radiology, July 1, 2003; 228(1): 257 - 264.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2001 by the British Institute of Radiology.