BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rea, J A
Right arrow Articles by Fogelman, I
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rea, J A
Right arrow Articles by Fogelman, I
British Journal of Radiology 74 (2001),341-350 © 2001 The British Institute of Radiology

Full paper

Development of a phantom for morphometric X-ray absorptiometry

J A Rea, PhD G M Blake, PhD and I Fogelman, MD

Osteoporosis Screening and Research Unit, 16th Floor Guy's Tower, Guy's Hospital, St Thomas' Street, London SE1 9RT, UK

Morphometric X-ray absorptiometry (MXA) has recently been developed to assess vertebral deformity status using dual energy X-ray absorptiometry (DXA) machines. In contrast to bone densitometry, a vertebral morphometry phantom is not supplied by any machine manufacturer. The aim of this study was to develop a suitable phantom to quantify the accuracy and precision of the vertebral measurement software on three DXA scanners in vitro and to perform a weekly quality control (QC) scan over a 30-month period to evaluate any drift or changes in measurement accuracy over time. The phantom was constructed from Perspex and aluminium to simulate soft tissue and bone, respectively. 13 aluminium rectangles (each 30 mm wide, 25 mm high and 3 mm thick, with edges ("endplates") 6 mm thick) were set into one side of a solid Perspex block to represent the vertebral bodies from the fourth thoracic (T4) to the fourth lumbar (L4). The phantom was scanned on both the Hologic QDR2000plus and the QDR-4500A as well as the Lunar Expert-XL. Three consecutive lateral MXA scans were acquired on the Hologic machines using each of the scan modes available. On the QDR-2000plus, the lateral scan modes available are fast, array and high definition, which are all dual energy modes. These three scan modes are also available on the QDR-4500A, with the addition of a single energy scan mode. Four lateral scans were acquired on the Expert-XL machine using the single scan mode available. Each MXA scan was analysed twice by a trained operator using the standard software supplied by each manufacturer. A QC scan was performed approximately weekly over a 30-month period on only the QDR-4500A machine, and total phantom height was measured from the inferior edge of L4 to the superior edge of T4. Accuracy of "vertebral" height measurement varied between the three DXA machines and between the scan modes available. All underestimated "true" vertebral height by between 0.4% and 8.6%, with the scan modes using finer collimation producing the most accurate results. Repeat analysis precision of vertebral height measurement was best on the QDR-4500A, followed by the Expert-XL, and was poorest on the QDR-2000plus. The QC scans acquired on the QDR-4500A suggested that it was a highly stable machine, little affected by even major repairs. It must be remembered that these in vitro phantom results may not be representative of the true in vivo situation. The MXA phantom appears to be a useful tool for documenting the stability of the mechanical instruments and for checking the long-term consistency of operator precision.




This article has been cited by other articles:


Home page
J. Clin. Endocrinol. Metab.Home page
E. M. Lewiecki and A. J. Laster
Clinical Applications of Vertebral Fracture Assessment by Dual-Energy X-Ray Absorptiometry
J. Clin. Endocrinol. Metab., November 1, 2006; 91(11): 4215 - 4222.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2001 by the British Institute of Radiology.