BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Robson, K J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Robson, K J
British Journal of Radiology 74 (2001),335-340 © 2001 The British Institute of Radiology

Full paper

A parametric method for determining mammographic X-ray tube output and half value layer

K J Robson, BSc

Regional Medical Physics Department, Newcastle General Hospital, Westgate Road, Newcastle upon Tyne NE4 6BE, UK

In the National Health Service Breast Screening Programme, regular assessment of the mean glandular doses received by a group of women is recognized as an important part of a quality assurance programme. The use of different tube voltages, to improve the beam penetration for thick or dense breasts, and of X-ray units with programmable exposure modes, requires a large number of measurements to ensure that all the values of tube output and half value layer required for the dose calculations are available. In this work, a computer model is used to produce data that allow the calculation of tube output and half value layer for the range of clinically encountered conditions from measurements routinely obtained during quality assurance tests. The data are given as a series of equations and parameters, enabling the calculations to be easily incorporated into a dose calculation spreadsheet. The results of an experimental verification of the model are presented, showing good agreement between the measured and predicted values of half value layer and tube output for a range of combinations of target, filter and tube voltage.




This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
S. Avramova-Cholakova, J. Vassileva, R. Borisova, and I. Atanasova
AN ESTIMATE OF THE INFLUENCE OF THE MEASUREMENT PROCEDURE ON PATIENT AND PHANTOM DOSES IN BREAST IMAGING
Radiat Prot Dosimetry, April 21, 2008; (2008) ncn139v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. Michielsen, J. Jacobs, K. Lemmens, J. Nens, J. Zoetelief, K. Faulkner, and H. Bosmans
RESULTS OF A EUROPEAN DOSE SURVEY FOR MAMMOGRAPHY
Radiat Prot Dosimetry, April 21, 2008; (2008) ncn152v1.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2001 by the British Institute of Radiology.