BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Crawley, M T
Right arrow Articles by Weatherburn, H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Crawley, M T
Right arrow Articles by Weatherburn, H
British Journal of Radiology 74 (2001),259-261 © 2001 The British Institute of Radiology

Short communication

Calibration frequency of dose–area product meters

M T Crawley, MSc, MIPEM 1 S Mutch, MSc, MIPEM 2 M Nyekiova, MSc, MIPEM 2 C Reddy, MSc 2 and H Weatherburn, PhD, MIPEM 2

1 Radiology Department, Stoke Mandeville Hospital, Mandeville Road, Aylesbury, Buckinghamshire HP21 8AL 2 Medical Physics Department, Oxford Radcliffe Hospital, Old Road, Headington, Oxford, OX3 7LJ, UK

Calibration of patient dose monitoring devices in diagnostic radiology has become increasingly important in the light of new legislation that requires monitoring of patient dose against local and national diagnostic reference levels. An investigation was conducted into the long-term stability of 41 dose–area product (DAP) meters over a period of approximately 5 years, to assess the suitability of an annual calibration regimen. For DAP meters fitted to overcouch X-ray tubes, 77% of calibrations were within 10%, whilst for undercouch tubes only 50% of calibrations were within 10%. These findings suggest that annual calibration may be too infrequent. Suitable calibration frequencies for different clinical workloads are discussed.




This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
J. Jankowski, J. Domienik, S. Papierz, R. Padovani, E. Vano, and K. Faulkner
An international calibration of kerma-area product meters for patient dose optimisation study
Radiat Prot Dosimetry, March 4, 2008; (2008) ncn018v1.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
J S Nettleton and J R Gill
Calibration frequency of DAP meters
Br. J. Radiol., January 1, 2001; 74(887): 1078 - 1079.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2001 by the British Institute of Radiology.