BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Thacker, N A
Right arrow Articles by Jackson, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thacker, N A
Right arrow Articles by Jackson, A
British Journal of Radiology 74 (2001),234-242 © 2001 The British Institute of Radiology

Full paper

Mathematical segmentation of grey matter, white matter and cerebral spinal fluid from MR image pairs

N A Thacker, BSc, PhD and A Jackson, PhD, MRCP, FRCR

Imaging Science and Biomedical Engineering, University of Manchester, Stopford Medical School, Oxford Road, Manchester M13 9PT, UK

The aims of this study were (1) to design a mathematical segmentation technique to allow extraction of grey matter, white matter and cerebral spinal fluid volumes from paired high resolution MR images and (2) to document the statistical accuracy of the method with different image combinations. A series of linear equations were derived that describe proportional tissue volumes in individual image voxels. The equations use estimates of pure tissue values to derive the proportion of each tissue within a single voxel. Repeatability of manual estimations of pure tissue values was assessed both using regions of interest and thresholding techniques. Statistical accuracy of tissue estimations for a variety of image pairs was assessed from measurements of root-mean-square noise and mean grey level intensity. The technique was used to produce parametric images of grey and white matter distribution. The segmentation technique showed greatest statistical accuracy when the first image has high grey/white matter contrast and the second image has little contrast or the rank order of the signal intensities from pure tissue is reversed. A combination of inversion recovery fast spin echo and fast FLAIR images produced a statistical error of 11% for grey matter and 10% for white matter for any given voxel. The effect of increasing sample size improves both of these figures to give a 1% statistical error on a 100 pixel sample.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2001 by the British Institute of Radiology.