BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tothill, P
Right arrow Articles by Wilkinson, S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tothill, P
Right arrow Articles by Wilkinson, S
British Journal of Radiology 74 (2001),166-176 © 2001 The British Institute of Radiology

Full paper

Comparisons between a pencil beam and two fan beam dual energy X-ray absorptiometers used for measuring total body bone and soft tissue

P Tothill, PhD, FRSE1, W J Hannan, PhD, FIPEM1 and S Wilkinson, BSc2

1 Department of Medical Physics, Western General Hospital, Edinburgh EH4 2XU
2 Osteoporosis Research Unit, Woolmanhill Hospital, Aberdeen AB25 1LD, UK

A pencil beam Hologic QDR 1000W scanner (1000), a fan beam QDR 4500A scanner (4500) and a fan beam Lunar Expert scanner (Expert) were compared for bone mineral and body composition measurement accuracy. Phantoms were scanned with each instrument to assess magnification effects and to compare calibrations for bone mineral and fat proportion. 41 volunteers were scanned with both the 1000 and the 4500, and 21 patients with both the 4500 and the Expert. The height of a bone within the body affected the measured bone mineral content (BMC) and, to a lesser extent, the bone mineral density (BMD). There were differences in calibration against recognized standards for fat proportion between the three instruments. The 1000 underestimated low fat proportions and the 4500 underestimated high fat proportions. Fat results for the Expert were closer to nominal values. Comparisons on volunteers showed that measured mean total body BMD was 4% higher and BMC was 7% higher with the 1000 compared with the 4500; some regional differences were greater. Mean values of per cent fat were equal, but the total and regional regression coefficients were well above unity. Mean BMD was 3% higher and mean BMC was 10% higher with the Expert compared with the 4500, but most regression coefficients for these comparisons were less than unity. Mean values of per cent fat were equal, but regression coefficients were above unity. Errors due to magnification are acceptable. Differences between the instruments are appreciable, but can be accommodated by cross-calibration.




This article has been cited by other articles:


Home page
Am. J. Clin. Nutr.Home page
H. C Lukaski
In search of a practical tool to assess regional body composition
Am. J. Clinical Nutrition, October 1, 2008; 88(4): 875 - 876.
[Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
M. J. Bolland, A. B. Grey, G. D. Gamble, and I. R. Reid
Low Body Weight Mediates the Relationship between HIV Infection and Low Bone Mineral Density: A Meta-Analysis
J. Clin. Endocrinol. Metab., December 1, 2007; 92(12): 4522 - 4528.
[Abstract] [Full Text] [PDF]


Home page
Ann Rheum DisHome page
M Guler-Yuksel, J Bijsterbosch, Y P M Goekoop-Ruiterman, F C Breedveld, C F Allaart, J K de Vries-Bouwstra, B A C Dijkmans, W F Lems, H K Ronday, A J Peeters, et al.
Bone mineral density in patients with recently diagnosed, active rheumatoid arthritis
Ann Rheum Dis, November 1, 2007; 66(11): 1508 - 1512.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
W. S. Gozansky, R. E. Van Pelt, C. M. Jankowski, R. S. Schwartz, and W. M. Kohrt
Protection of Bone Mass by Estrogens and Raloxifene during Exercise-Induced Weight Loss
J. Clin. Endocrinol. Metab., January 1, 2005; 90(1): 52 - 59.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2001 by the British Institute of Radiology.